... Current/Voltage: 19 amperes (2 position with 10 AWG wire) at 600 volts AC ! Operating temperature: -55 to 125° C ©2011 Tyco Electronics Corporation, | Indicates change a TE Connectivity Ltd. Company *Trademark All Rights Reserved TE logo is a trademark. For latest revision, visit our website at www.te.com/documents. For Regional Customer Service, visit our website at www.te.com Other products, logos, and company names might be trademarks of their respective owners ...
Page 2
Performance and Test Description Product is designed to meet the electrical, mechanical and environmental performance requirements specified in Figure 1. 3.5. Test Requirements and Procedures Summary Test Description Examination of product. Termination resistance, specified current. Termination resistance, dry circuit. ...
Page 3
Test Description Physical shock. Mating force. Unmating force. Contact insertion force. Contact retention force. Crimp tensile. Durability. Housing panel retention. Rev L Requirement No discontinuities greater than 10 microseconds. 6.0 milliohms maximum termination resistance, dry circuit. See Note (b). Will ...
Page 4
Test Description Housing lock strength. Thermal shock. Humidity/temperature cycling. Salt spray corrosion. (a) Maximum rated current that can be carried by this product is limited by maximum operating NOTE temperature of housings which is 105° C and temperat ure rise ...
Page 5
Product Qualification and Requalification Test Sequence Test or Examination Examination of product Termination resistance, specified current Termination resistance, dry circuit Dielectric withstanding voltage Insulation resistance Temperature rise vs current Vibration Physical shock Mating force Unmating force Contact insertion force ...
Page 6
QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Sample Selection Connector housings and contacts shall be prepared in accordance with applicable Instruction Sheets and shall be selected at random from current production. Test group 1 shall consist of 1 housing ...
Page 7
A 1 foot minimum length of continuous lead for heat dissipation. NOTE 2. Termination resistance equals millivolts divided by test current less resistance of 6 inches of wire. Rev L Figure 3 Termination Resistance Measurement Points 108-1031 7 of ...
Page 8
Terminal Temperature vs Current/Circuit, Phosphor Bronze Contacts, Terminal Temperature vs Current/Circuit, Phosphor Bronze Contacts, Rev L Figure 4 4 Circuit Free Hanging Housing Figure 5 12 Circuit Free Hanging Housing 108-1031 ...