AD7732BRU Analog Devices Inc, AD7732BRU Datasheet - Page 23

no-image

AD7732BRU

Manufacturer Part Number
AD7732BRU
Description
Analog/Digital Converter IC Number Of Bits:24
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7732BRU

Interface Type
Serial
Supply Voltage Max.
5V
Package/case
24-TSSOP
Leaded Process Compatible
No
A/d, D/a Features
DSP, MicroWire, QSPI, SPI
Adc Resolution
24-Bit
Rohs Status
RoHS non-compliant
Number Of Bits
24
Sampling Rate (per Second)
15.4k
Data Interface
DSP, MICROWIRE™, QSPI™, Serial, SPI™
Number Of Converters
1
Power Dissipation (max)
100mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
28-TSSOP (0.173", 4.40mm Width)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
EVAL-AD7732EBZ - BOARD EVAL FOR AD7732
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7732BRU-REEL7
Manufacturer:
TI
Quantity:
16 700
Part Number:
AD7732BRUZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7732BRUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7732BRUZ-REEL7
Manufacturer:
ADI
Quantity:
1 000
Reset
The AD7732 can be reset by the RESET pin or by writing a reset
sequence to the AD7732 serial interface.
The reset sequence is N × 0 + 32 × 1, which could be the data
sequence 00h + FFh + FFh + FFh + FFh in a byte-oriented
interface. The AD7732 also features a power-on reset with a
trip point of 2 V and goes to the defined default state after
power-on.
It is the system designer’s responsibility to prevent an unwanted
write operation to the AD7732. The unwanted write operation
could happen when a spurious clock appears on the SCLK while
the CS pin is low. It should be noted that on system power-on, if
the AD7732 interface signals are floating or undefined, the part
can be inadvertently configured into an unknown state. This
could be easily overcome by initiating either a hardware reset
event or a 32 ones reset sequence as the first step in the system
configuration.
Access the AD7732 Registers
All communications to the part start with a write operation to
the communications register followed by either reading or
writing the addressed register.
In a simultaneous read-write interface (such as SPI), write 0 to
the AD7732 while reading data.
Figure 16 shows the AD7732 interface read sequence for the
ADC status register.
DOUT
SCLK
RDY
DIN
CS
COMMUNICATIONS
REGISTER
Figure 17. Serial Interface Signals—Single Conversion Command and 16-Bits Data Reading
WRITE
38h
REGISTER
WRITE
MODE
40h
CONVERSION TIME
Rev. 0 | Page 23 of 32
COMMUNICATIONS
Single Conversion and Reading Data
When the mode register is being written, the ADC status byte is
cleared and the RDY pin goes high, regardless of its previous
state. When the single conversion command is written to the
mode register, the ADC starts the conversion on the channel
selected by the address of the mode register. After the
conversion is completed, the data register is updated, the mode
register is changed to idle mode, the relevant RDY bit is set,
and the RDY pin goes low. The RDY bit is reset and the RDY
pin returns high when the relevant channel data register is
being read.
Figure 17 shows the digital interface signals executing a single
conversion on Channel 0, waiting for the RDY pin to go low,
and reading the Channel 0 data register.
REGISTER
WRITE
48h
Figure 16. Serial Interface Signals—Registers Access
DOUT
SCLK
DIN
CS
DATA
READ DATA REGISTER
(00h)
COMMUNICATIONS
REGISTER
WRITE
DATA
(00h)
ADC STATUS
REGISTER
READ
AD7732

Related parts for AD7732BRU