ADUM1311ARWZ-RL Analog Devices Inc, ADUM1311ARWZ-RL Datasheet - Page 12

no-image

ADUM1311ARWZ-RL

Manufacturer Part Number
ADUM1311ARWZ-RL
Description
IC,Digital Coupler,HYBRID,SOP,16PIN,PLASTIC
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM1311ARWZ-RL

Inputs - Side 1/side 2
2/1
Number Of Channels
3
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
1Mbps
Propagation Delay
100ns
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
105C
Package Type
SOIC W
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM1311ARWZ-RL
Manufacturer:
MICREL
Quantity:
15 000
Part Number:
ADUM1311ARWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuM1310/ADuM1311
ABSOLUTE MAXIMUM RATINGS
T
Table 9.
Parameter
Storage Temperature (T
Ambient Operating Temperature
Supply Voltages (V
Input Voltage
Output Voltage (V
Average Output Current per Pin
Common-Mode Transients
1
2
3
4
Table 10. Maximum Continuous Working Voltage
Parameter
AC Voltage, Bipolar Waveform
AC Voltage, Unipolar Waveform
Basic Insulation
Reinforced Insulation
DC Voltage
Basic Insulation
Reinforced Insulation
1
All voltages are relative to their respective ground.
V
given channel, respectively. See the PC Board Layout section.
See Figure 3 for maximum rated current values for various temperatures.
Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the absolute maximum ratings may cause
latch-up or permanent damage.
Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.
A
DDI
(T
(V
Side 1 (I
Side 2 (I
= 25°C, unless otherwise noted.
A
IA
and V
) Range
, V
IB
, V
DDO
O1
O2
IC
, V
)
)
refer to the supply voltages on the input and output sides of a
DISABLE
OA
DD1
, V
, V
CTRL1
, V
OB
ST
DD2
, V
, V
) Range
)
OC
CTRL2
1
4
)
1, 2
)
1, 2
3
Max
565
1131
560
1131
560
Rating
−65°C to +150°C
−40°C to +105°C
−0.5 V to +7.0 V
−0.5 V to V
−0.5 V to V
−18 mA to +18 mA
−22 mA to +22 mA
−100 kV/μs to +100 kV/μs
Unit
V peak
V peak
V peak
V peak
V peak
DDI
DDO
+ 0.5 V
+ 0.5 V
1
Constraint
50-year minimum lifetime
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
Rev. G | Page 12 of 24
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION

Related parts for ADUM1311ARWZ-RL