ADUM1311ARWZ-RL Analog Devices Inc, ADUM1311ARWZ-RL Datasheet - Page 9

no-image

ADUM1311ARWZ-RL

Manufacturer Part Number
ADUM1311ARWZ-RL
Description
IC,Digital Coupler,HYBRID,SOP,16PIN,PLASTIC
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM1311ARWZ-RL

Inputs - Side 1/side 2
2/1
Number Of Channels
3
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
1Mbps
Propagation Delay
100ns
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
105C
Package Type
SOIC W
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM1311ARWZ-RL
Manufacturer:
MICREL
Quantity:
15 000
Part Number:
ADUM1311ARWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Parameter
1
2
3
4
5
6
7
8
9
10
The supply current values for all four channels are combined when running at identical data rates. Output supply current values are specified with no output load
present. The supply current associated with an individual channel operating at a given data rate can be calculated as described in the Power Consumption section.
See Figure 6 through Figure 8 for information on per-channel supply current as a function of data rate for unloaded and loaded conditions. See Figure 9 through
Figure 12 for total V
The minimum pulse width is the shortest pulse width at which the specified pulse width distortion is guaranteed.
The maximum data rate is the fastest data rate at which the specified pulse width distortion is guaranteed.
t
measured from the 50% level of the rising edge of the V
t
within the recommended operating conditions.
Codirectional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with inputs on the same side of
CM
that can be sustained while maintaining V
magnitude is the range over which the common mode is slewed.
Input enable time is the duration from when V
transitions. If an input data logic transition within a given channel does occur within this time interval, the output of that channel reaches the correct state within the
much shorter duration, as determined by the propagation delay specifications within this data sheet. Input disable time is the duration from when V
until the output states are guaranteed to reach their programmed output levels, as determined by the CTRL
I
the same orientation as Channel A must be included to account for the total current consumed.
on per-channel supply current for unloaded and loaded conditions. See the Power Consumption section for guidance on calculating the per-channel supply current
for a given data rate.
the isolation barrier. Opposing-directional channel-to-channel matching is the absolute value of the difference in propagation delays between any two channels with
inputs on opposing sides of the isolation barrier.
DDx (Q)
PHL
PSK
Dynamic supply current is the incremental amount of supply current required for a 1 Mbps increase in signal data rate. See Figure 6 through Figure 8 for information
H
is the magnitude of the worst-case difference in t
propagation delay is measured from the 50% level of the falling edge of the V
Output Dynamic Supply Current
is the maximum common-mode voltage slew rate that can be sustained while maintaining V
is the quiescent current drawn from the corresponding supply by a single channel. To calculate the total quiescent current, an additional inaccessible channel in
V
V
per Channel
DDX
DDX
= 5 V Operation
= 3 V Operation
DD1
10
and V
DD2
supply currents as a function of data rate for ADuM1310/ADuM1311 channel configurations.
O
< 0.8 V. The common-mode voltage slew rates apply to both rising and falling common-mode voltage edges. The transient
DISABLE
Symbol
I
DDI (D)
is set low until the output states are guaranteed to match the input states in the absence of any input data logic
PHL
or t
Ix
signal to the 50% level of the rising edge of the V
PLH
that is measured between units at the same operating temperature, supply voltages, and output load
Min
Rev. G | Page 9 of 24
Ix
signal to the 50% level of the falling edge of the V
Typ
0.04
0.02
O
> 0.8 V
DD2
Ox
2
. CM
signal.
logic state (see Table 13).
Max Unit
L
is the maximum common-mode voltage slew rate
mA/
Mbps
mA/
Mbps
ADuM1310/ADuM1311
Test Conditions
Ox
signal. t
PLH
propagation delay is
DISABLE
is set high