CS5464-ISZR Cirrus Logic Inc, CS5464-ISZR Datasheet - Page 23

no-image

CS5464-ISZR

Manufacturer Part Number
CS5464-ISZR
Description
IC 3-Channel Single Phase Power/Energy
Manufacturer
Cirrus Logic Inc
Type
Single Phase Power/Energy ICr
Datasheet

Specifications of CS5464-ISZR

Input Impedance
30 KOhm
Measurement Error
0.1%
Voltage - I/o High
0.8V
Voltage - I/o Low
0.2V
Current - Supply
3.5mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
28-SSOP
Meter Type
Single Phase
Output Voltage Range
2.4 V to 2.6 V
Output Current
100 mA
Input Voltage Range
3.135 V to 5.25 V
Input Current
10 mA
Power Dissipation
500 mW
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1554 - BOARD EVAL FOR CS5464 ADC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
7.4 Command Interface
Commands and data are transferred most-significant bit
(MSB) first.
timing. Commands are clocked in on SDI using SCLK.
They are a single byte (8 bits) long and fall into one of
four basic types:
1. Register Read
2. Register Write
3. Synchronizing
4. Instructions
Register reads will cause up to four bytes of register
data to be clocked out, MSB first on the SDO pin by
SCLK. During this time, other commands can be
clocked in on the SDI pin. Other commands will not in-
terrupt read data, except another register read, which
will cause the new read data to appear on SDO.
Synchronizing can be sent while read data is being
clocked out if no other commands need to be sent.
DS682F1
Figure 1
on page 12, defines the serial port
Synchronizing commands are also used to synchronize
the serial port to a byte boundary. The CS and RESET
pins will also synchronize the serial port.
Register writes require three bytes of write data to fol-
low, clocked in on the SDI pin, MSB first by SCLK.
Instructions are commands that will interrupt any in-
struction currently executing and begin the new instruc-
tion. These include conversions, calibrations, power
control, and soft reset.
(See
7.5 Register Paging
Read and Write commands access one of 32 registers
within a specified page. The Resgister Page Select reg-
ister’s ( Page ) default value is 0. To access registers in
another page, write the desired page number to the
Page register. The Page register is always at address
31 and is accessible from within any page.
Section 7.6 Commands
on page 24).
CS5464
23

Related parts for CS5464-ISZR