1986165-2 TE Connectivity, 1986165-2 Datasheet

USE-2 SOLAR WIRE, 500FT, 12AWG, CU, BLK

1986165-2

Manufacturer Part Number
1986165-2
Description
USE-2 SOLAR WIRE, 500FT, 12AWG, CU, BLK
Manufacturer
TE Connectivity
Type
Power Cabler
Datasheet

Specifications of 1986165-2

Cable Length
500
Conductor Material
Tin Plated Copper
Cable Diameter
4.82mm
Wire Size
12AWG
Number Of Conductors
1
Color
Black
Cable Pitch (mm)
Not Required
Reel Length (imperial)
500ft
Reel Length (metric)
152.4m
Conductor Size Awg
12
Conductor Area Csa
3.31mm
Jacket Color
Black
External Diameter
4.826mm
Rohs Compliant
Yes
Color, Jacket
Black
Conductor Size
12 AWG
Insulation Material
Electron beam cross-linked Polyolefin
Material, Conductor
Stranded tin-plated copper
Standards
UL File E214122 and E314125, USE-2, RHH, RHW-2, XHH, XHHW-2 and Approved, VW-1 Flammability
Temperature, Operating
–40°C to +120°C
Voltage, Rating
1800/2600 VAC/VDC
Max Conductor Temperature
90° Wet or Dry
Voltage Rating
600 Volts (UL)
Product Type
Cable
Cable Type
RHH, RHW-2, XHHW and USE-2 Rated, UL 854 Approved
Wire Size (mm² [awg])
4.0² [12]
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Converted to comply with RoHS directive
Packaging Quantity
500 Ft. per Reel
Lead Free Status / RoHS Status
Compliant
SOLARLOK
Interconnection System
RoHS
Ready

1986165-2 Summary of contents

Page 1

SOLARLOK Interconnection System RoHS Ready ...

Page 2

SOLARLOK Interconnection System Table of Contents The SOLARLOK Concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 3

SOLARLOK Interconnection System The SOLARLOK Concept System Features Junction Box ■ Variable wiring options ■ Easily accessible ■ Simple, fast and cost-effective assembly ■ Flat, low profile design ■ High current carrying capacity ■ Good thermal balance ■ Connectorized or ...

Page 4

SOLARLOK Interconnection System Large Junction Box – Serial Interconnection Part Configuration Number 1-1394723-6 2-1394723-6 0-1394723-4 0-1394723-3 2 All specifications subject to change. Consult Tyco Electronics for latest specifications ...

Page 5

SOLARLOK Interconnection System Large Junction Box – Parallel Interconnection Part Package Configuration Number Quantity 1394723-5 1394723-6 1394723-9 ...

Page 6

SOLARLOK Interconnection System Medium Junction Box – Serial Interconnection Part Configuration Number 1740699-1 ✱ 1740699-6 1740700-1 ✱✱ 1740700-3 1740971-1 ✱ 1740971-2 1740972-1 ✱✱ 1740972-3 ✱✱ ) Junction Box Assembly with two 100 cm long 4.0 mm ✱✱ ) Junction Box ...

Page 7

SOLARLOK Interconnection System Medium Junction Box – Serial Interconnection Part Configuration Number 0-1740657-7 ✱ 0-1740657-8 0-1740658-1 ✱✱ 0-1740658-3 0-1740657-9 ✱ 1-1740657-0 0-1740658-4 ✱✱ 0-1740658-5 ✱✱ ) Junction Box Assembly with two 100 cm long 4.0 mm ✱✱ ) Junction Box ...

Page 8

SOLARLOK Interconnection System Small Junction Box – Serial Interconnection Part Configuration Number 1740220-4 1740220-2 ✱ ✱ 1740425-3 1740220-3 1740220-1 ✱✱ ✱✱ 1740425-1 ✱✱ ) Junction Box Assembly with two 70 cm long 4.0 mm ✱✱ ) Junction Box Assembly with ...

Page 9

SOLARLOK Interconnection System Small Junction Box – Serial Interconnection Part Configuration Number 0-1418867-2 0-1418867-5 ✱ 1-1418867-3 0-1418867-1 0-1418867-6 ✱✱ 1-1418867-2 ✱✱ ) Junction Box Assembly with one 140 cm long 4.0 mm ✱✱ ) Junction Box Assembly with one 170 ...

Page 10

SOLARLOK Interconnection System Mini Junction Box – Serial Interconnection Part Configuration Number 1740863-1 1740863-2 ✱ ) Junction Box Assembly with two 85 cm long 4 All specifications subject to change. Consult Tyco Electronics for latest specifications ...

Page 11

SOLARLOK Interconnection System Cable Coupler Female Cable Coupler Wire Size 2 (mm ) Plus Keyed 2.5 0-1394462-1 4.0 0-1394462-3 6.0 5-1394462-5 Male Cable Coupler Not Keyed, only for Junction Box Serial Interconnection All specifications subject to change. Consult Tyco Electronics ...

Page 12

SOLARLOK Interconnection System T-Branch Connector Parallel Interconnection using T-Branch Connector (Male-to-Male) Parallel Interconnection using T-Branch Connector (Female-to-Male) 10 All specifications subject to change. Consult Tyco Electronics for latest specifications. T-Branch Connector Plus Keyed Minus Keyed o o T-Branch Connector Plus ...

Page 13

SOLARLOK Interconnection System DC/AC Converter Receptacle O-Ring and Metal Nut Wire Size Keying 2 2 2.5 mm 4.0 mm Plus (AWG 14) (AWG 12 ...

Page 14

SOLARLOK Interconnection System AC Inverter Connector Product Facts ■ Current Rating ■ Voltage Rating: 400 V ■ Protection Degree: IP67 (mated) ■ No. of Positions: 5 Poles ■ Temperature Range: –40 ° +50 °C ■ Wire ...

Page 15

SOLARLOK Interconnection System Solar Cable Product Facts ■ Dual wall insulation ■ Electron beam cross-linked ■ Excellent resistance to UV, water, ozone, fluids, salt, general weathering ■ Excellent resistance to abrasion ■ Halogen free, flame retardant, low toxicity ■ Very ...

Page 16

... Blue 1-956298-6 0-956299-4 Black 1-956299-4 0-956299-5 0.24 Red 1-956299-5 0-956299-6 Blue 1-956299-6 Color Part Number (Inch) -1986166-2 0.17 Black -1986166-3 -1986165-2 0.19 Black -1986165-3 -1986164-2 0.21 Black -1986164-3 Catalog 889753-3 Revised 6-2008 Package Quantity Approbation (m) (Feet) TÜV 500 – o 100 – ...

Page 17

SOLARLOK Interconnection System Field Wiring, Switching and Protection Product Features Switching ■ Modular product concept ■ One- / two-pole switches ■ Current ■ Voltage up to 1000 VDC ■ Compact, standardized design ■ Proven quality ...

Page 18

... SOLARLOK Interconnection System Wiring Example with Extension Cables 2 Male Cable Coupler (+) 1 1394461-3 Male Cable Coupler (–) 2 1394461-4 Female Cable Coupler (+) 3 1394462-3 2 Configuration Example at 4 Cable Assembly Wire Size: 2 4.0 mm Color: Black More variants (cable length, wire diameter, color) upon request. 16 All specifications subject to change. Consult Tyco Electronics for latest specifications. ...

Page 19

... SOLARLOK Interconnection System Wiring Example with Extension Cables 5 4 Male Cable Coupler (+) 1 1394461-3 Male Cable Coupler (–) 2 1394461-4 Female Cable Coupler (+) 3 1394462-3 Female Cable Coupler (–) 4 1394462-4 Female Cable Coupler (–) 5 1394462-4 2 Configuration Example at 4 Cable Assembly Wire Size: 2 4.0 mm Color: Black More variants (cable length, wire diameter, color) upon request ...

Page 20

SOLARLOK Interconnection System SolKlip™ – Ground Clip Product Features ■ Self-tapping screw ■ Quick and easy mounting ■ Four-point contact to wire ■ Low interface resistance ■ Toolless termination ■ Re-terminateable times ■ UV resistant ■ Weather-proof ...

Page 21

SOLARLOK Interconnection System SolKlip™ – Ground Clip 3 Easy Steps to Ground Your PV System Yesterday Insert ... ... Push ... Today ... Ready! Description Electrical SolKlip ground clips are designed The electrical performance of for solar panel grounding appli- ...

Page 22

SOLARLOK Interconnection System Interconnection Examples Serial Interconnection for Junction Boxes with Cable Glands 1394462-4 1394461-4 1394462-4 1394738-4 20 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2 (4.0 mm Wiring) DC/AC Converter Catalog 889753-3 Revised 6-2008 6-1394461-2 ...

Page 23

SOLARLOK Interconnection System Interconnection Examples Serial Interconnection for Junction Boxes with Plug Connectors 1394462-4 1394462-3 1394462-4 1394738-4 All specifications subject to change. Consult Tyco Electronics for latest specifications. (continued) 2 (4.0 mm Wiring) 1394462-4 DC/AC Converter Catalog 889753-3 Revised 6-2008 ...

Page 24

SOLARLOK Interconnection System Application Tooling Cable Assembly Tooling SOLARLOK Electric Terminator CS 200 Base Machine: Part No. 539630-1 22 All specifications subject to change. Consult Tyco Electronics for latest specifications. Catalog 889753-3 Revised 6-2008 Hand Crimping Tool incl. Vario Crimp ...

Page 25

SOLARLOK Interconnection System Application Tooling Junction Box Assembly Tooling Field Service Kit Part No. 1534858-1 (Metric Wire) All specifications subject to change. Consult Tyco Electronics for latest specifications. (continued) Catalog 889753-3 Revised 6-2008 Wire Spring Clamp Tool Part No. 1579007-2 ...

Page 26

... SOLARLOK Plug Connector Attention: This connector used only to interconnect firmly fixed cables. Do not disconnect under load. Current path should only be disconnected using approved disconnect devices. Cable assemblies shall be labeled with Part No. 1394470-1. To protect against shock, ensure that conductors and their associated connectors are separated from opposite polarity components ...

Page 27

SOLARLOK Interconnection System Assembly and Installation Guidelines When assembling the connectors, the following sequence must be followed: 1 Stripping the Wire (please refer to application specification # 114-74013) 8 Insert the stripped wire into the wire crimp barrel ...

Page 28

SOLARLOK Interconnection System Assembly and Installation Guidelines 3.2 Connector Latching When mating the SOLARLOK connectors, ensure the following: ■ Connectors labeled with a plus or minus are keyed and can only be mated to similarly marked and keyed connectors. The ...

Page 29

SOLARLOK Interconnection System Assembly and Installation Guidelines 1 Place a single wire seal onto the wire and strip wire 3.4 DC/AC Converter Receptacle (single wire seals are not available with every version). 2 Crimp the contact using the correct applicator ...

Page 30

SOLARLOK Interconnection System Assembly and Installation Guidelines 4. Application Examples Fig. 14: Serial (Wire Diagram) 5. Storage See Product Specification 108-18701 ■ 6. Tooling The following tools are available for the contact crimping (please specify wire gauge required): ● ● ...

Page 31

SOLARLOK Interconnection System Technical Data (Junction Box and One Pole Plug Connectors) Materials Socket and Pin Contacts: Housing: Color Connector, Junction Box: Electrical Features Withstanding Voltage: Current Rating: Contact Resistance: Contact Resistance (typical): Protection Class: Mechanical Features Junction Boxes Dimensions: ...

Page 32

... Catalog 889753-3 Revised 6-2008 Page Part Number Page 11 1987376-2 16 1987376-3 16 1987376-4 16 1987376-5 16 1-1987376-1 16 1-1987376-2 16 1-1987376-3 16, 17 ...

Page 33

SOLARLOK Interconnection System Restriction on the Use of Hazardous Substances (RoHS) Restriction on the Use At Tyco Electronics, we’re ready to support your RoHS requirements. We’ve assessed more than 1.5 million end items/components for RoHS compliance, and issued new part ...

Page 34

SOLARLOK Interconnection System Engineering Notes 32 All specifications subject to change. Consult Tyco Electronics for latest specifications. Catalog 889753-3 Revised 6-2008 ...

Page 35

Americas Argentina – Buenos Aires Canada – Toronto Phone: +54-11-4733-2200 Phone: +1-905-475-6222 Fax: +54-11-4733-2211 Fax: Product Information Center: Brasil – São Paulo Phone: +1-905-470-4425 Phone: +55-11-3611-1311 Fax: Fax: +55-11-3611-0397 Colombia – Bogota Phone: +57-1-231-9398 Fax: Asia/Pacific Australia – Sydney Japan ...

Page 36

Tyco Electronics AMP GmbH Siemensstr. 13 67346 Speyer / Germany Phone: +49-(0)6232-30-2520 Fax: +49-(0)6232-30-2243 www.tycoelectronics.com AMP, SOLARLOK, SOLKLIP, TE Logo and Tyco Electronics are trademarks. © 2008 Tyco Electronics Ltd. 889753-3 Revised 6-2008 5M ST ...