1367337-1 TE Connectivity, 1367337-1 Datasheet - Page 5

CONN RCPT 70POS RTANG .8MM SMD

1367337-1

Manufacturer Part Number
1367337-1
Description
CONN RCPT 70POS RTANG .8MM SMD
Manufacturer
TE Connectivity
Datasheets

Specifications of 1367337-1

Connector Style
Receptacle
Connector Type
PT
Number Of Positions
70
Mounting Type
Surface Mount, Right Angle
Termination
Solder
Features
Board Guide
Contact Finish
Gold
Contact Finish Thickness
15µin (0.38µm)
Gender
Receptacle
No. Of Contacts
70
Contact Termination
Surface Mount Horizontal
Connector Mounting
PCB
Contact Plating
Gold
Contact Material
Phosphor Bronze
Rohs Compliant
Yes
Product Type
Connector
Termination Type
Surface Mount
Pcb Mount
Double Sided (Belly-to-Belly)
Contact Plating, Mating Area, Material
Gold (15)
Contact Base Material
Phosphor Bronze
Housing Color
Black
Ul Flammability Rating
UL 94V-0
Housing Material
Liquid Crystal Polymer (LCP)
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Reflow solder capable to 245°C, Reflow solder capable to 260°C
Rohs/elv Compliance History
Always was RoHS compliant
Application
X2, XENPAK, XPAK
Packaging Method
Reel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
A100858DKR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1367337-1
Manufacturer:
TYCO
Quantity:
36 566
4.
4.1.
4.2.
4.3.
4.4.
Rev C
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form, fit or function are made to the product or manufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determined by development/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to
confirm corrective action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan shall specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
Specimen Selection
Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. All test groups shall each consist of 5 lower cages, 5
upper cages and 5 connectors.
Test Sequence
Qualification inspection shall be verified by testing specimens as specified in Figure 2.
108-1949