MTCBA-C1-EN2-N3-NAM Multi-Tech Systems, MTCBA-C1-EN2-N3-NAM Datasheet - Page 60

no-image

MTCBA-C1-EN2-N3-NAM

Manufacturer Part Number
MTCBA-C1-EN2-N3-NAM
Description
ROUTER WIRELESS DUAL CDMA
Manufacturer
Multi-Tech Systems
Series
MultiModem® rCellr
Datasheets

Specifications of MTCBA-C1-EN2-N3-NAM

Function
Transceiver, CDMA, Router
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz
Applications
Verizon™ Networks (USA)
Interface
RJ-45, RS-232
Features
US Power Cord
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1067
Slot Cycle Index +WSCI
Description:
committed to NV memory until the +WCMT command is issued. .
Syntax:
Values:
SID and NID +WSID
Description:
Syntax:
Values:
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
This command is used to set the slot cycle index. Changes made to this data will not be
Command syntax: AT+WSCI=<number>
<number> Slot cycle index; ranges from 0 to 7.
This command is used to set the home SID and NID for 800Mhz CDMA operation only. The new
SID/NID values are committed to NV with the +WCMT command.
Command syntax: AT+ WSID=<index>,<SID number>,<NID number>
<index>
<SID number>
<NID number>
Updating the first entry in the SID/NID list will update the A/B side setting with odd SID for A side
and even SID for B side.
Command
AT+WSCI?
Note: Read the current slot cycle
index
AT+WSCI=1
Note: Set the slot cycle index
Command
AT+WSID?
Note: Get all modified SID/NID pairs.
If no pairs have been modified, the
first entry in location 0 will be
retrieved.
AT+WSID=3, 4145, 2102
AT+WSID?
Note: Set SID to 4145 and NID to
2102. Store in location 3 of the
SID/NID list.
AT+WSID=2
AT+WSID?
Note: Set SID to 0 and NID to 0. Store
in location 2 of the SID/NID list.
AT+WSID=4, 64
AT+WSID?
Note: Set SID to 64 and NID to 0.
Store in location 4 of the SID/NID list.
AT+WSID=, 64, 1024
AT+WSID?
Note: Set SID to 64 and NID to 1024.
Store in the currently selected
location of the SID/NID list.
AT+WSID=, ,
AT+WSID?
Note: Set SID and NID to default
value 0. Store in the default selected
location of the SID/NID list.
The location in the SID/NID list to store the values. A maximum of 20 entries
(0-19) are supported. Error is returned if the specified index value is not in the
valid range.
SID value range – 0 to 32767.
NID value range – 0 to 65535. Defaults to 65535 if not specified.
Possible Responses
+WSCI: 2
OK
OK
Possible Responses
+WSID: 0, 45, 84
+WSID: 1, 56, 9
OK
OK
+WSID: 3, 4145, 2102
OK
Note: The SID/NID pair 4145,2102 in location 3 is
selected.
OK
+WSID: 2, 0, 0
OK
Note: The SID/NID pair 0,0 in location 2 is selected.
OK
+WSID: 4, 64, 0
OK
Note: The SID/NID pair 64,0 in location 4 is selected.
OK
+WSID: 4, 64, 1024
OK
Note: The SID/NID pair 64,1024 in location 4 is
selected.
OK
+WSID: 0, 0, 0
OK
Note: The SID/NID pair 0,0 in location 0 is selected.
Chapter 11 – Provisioning Control Commands
60

Related parts for MTCBA-C1-EN2-N3-NAM