KMA199E,115 NXP Semiconductors, KMA199E,115 Datasheet - Page 31

IC SENSOR PROG ANGLE SOT880

KMA199E,115

Manufacturer Part Number
KMA199E,115
Description
IC SENSOR PROG ANGLE SOT880
Manufacturer
NXP Semiconductors
Datasheet

Specifications of KMA199E,115

Position - Sensing
180°
Sensor Type
Angular - Magnetoresistive
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 160°C
Supply Current
10 mA
Maximum Operating Temperature
+ 160 C
Minimum Operating Temperature
- 40 C
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Package / Case
SOT-880
Output Type
Analog - Voltage
Operating Temperature (min)
-40C
Operating Supply Voltage (typ)
5V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-4329-2
934061291115
KMA199E T/R
KMA199E T/R
NXP Semiconductors
25. Contents
1
1.1
1.2
2
3
4
5
5.1
6
6.1
6.2
6.3
6.4
7
8
9
10
11
12
12.1
12.2
12.3
12.4
12.5
13
13.1
13.2
13.3
13.3.1
13.3.2
13.3.3
13.4
13.4.1
13.5
13.5.1
13.5.2
14
14.1
14.1.1
14.1.2
14.2
14.2.1
14.2.2
14.2.3
Product profile . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Pinning information . . . . . . . . . . . . . . . . . . . . . . 2
Ordering information . . . . . . . . . . . . . . . . . . . . . 2
Functional diagram . . . . . . . . . . . . . . . . . . . . . . 3
Functional description . . . . . . . . . . . . . . . . . . . 4
Diagnostic features . . . . . . . . . . . . . . . . . . . . . . 5
Analog output. . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Limiting values. . . . . . . . . . . . . . . . . . . . . . . . . . 8
Recommended operating conditions. . . . . . . . 8
Thermal characteristics. . . . . . . . . . . . . . . . . . . 8
Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Definition of errors. . . . . . . . . . . . . . . . . . . . . . 11
Programming . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Electromagnetic compatibility . . . . . . . . . . . . 24
General description. . . . . . . . . . . . . . . . . . . . . . 1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Angular measurement directions . . . . . . . . . . . 4
EEPROM CRC and EDC supervision. . . . . . . . 5
Magnet-lost detection . . . . . . . . . . . . . . . . . . . . 5
Power-lost detection . . . . . . . . . . . . . . . . . . . . . 6
Low supply voltage detection . . . . . . . . . . . . . . 6
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Hysteresis error . . . . . . . . . . . . . . . . . . . . . . . 11
Linearity error . . . . . . . . . . . . . . . . . . . . . . . . . 12
Microlinearity error . . . . . . . . . . . . . . . . . . . . . 12
Temperature drift error . . . . . . . . . . . . . . . . . . 13
General description. . . . . . . . . . . . . . . . . . . . . 13
Timing characteristics . . . . . . . . . . . . . . . . . . . 14
Sending and receiving data . . . . . . . . . . . . . . 15
Write access . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Read access . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Entering the command mode . . . . . . . . . . . . . 18
Cyclic redundancy check . . . . . . . . . . . . . . . . 18
Software example in C . . . . . . . . . . . . . . . . . . 19
Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Command registers . . . . . . . . . . . . . . . . . . . . 20
EEPROM registers . . . . . . . . . . . . . . . . . . . . . 21
Emission (CISPR 25) . . . . . . . . . . . . . . . . . . . 24
Conducted radio disturbance . . . . . . . . . . . . . 24
Radiated radio disturbance. . . . . . . . . . . . . . . 24
Radiated disturbances (ISO 11452-2,
ISO 11452-4 and ISO 11452-5) . . . . . . . . . . . 24
Absorber lined shielded enclosure . . . . . . . . . 24
Bulk-current injection . . . . . . . . . . . . . . . . . . . 24
Strip line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
14.2.4
14.3
14.3.1
15
15.1
15.2
16
17
18
19
20
21
22
23
23.1
23.2
23.3
23.4
24
25
Please be aware that important notices concerning this document and the product(s)
described herein, have been included in section ‘Legal information’.
© NXP B.V. 2007.
For more information, please visit: http://www.nxp.com
For sales office addresses, please send an email to: salesaddresses@nxp.com
ElectroStatic Discharge (ESD) . . . . . . . . . . . . 26
Application information . . . . . . . . . . . . . . . . . 26
Marking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Package outline . . . . . . . . . . . . . . . . . . . . . . . . 28
Handling information . . . . . . . . . . . . . . . . . . . 29
Solderability information . . . . . . . . . . . . . . . . 29
Revision history . . . . . . . . . . . . . . . . . . . . . . . 29
Legal information . . . . . . . . . . . . . . . . . . . . . . 30
Contact information . . . . . . . . . . . . . . . . . . . . 30
Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Immunity against mobile phones . . . . . . . . . . 25
Transients - pulses (ISO 7637-1 and
ISO 7637-3) . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Coupled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Human body model . . . . . . . . . . . . . . . . . . . . 26
Machine model. . . . . . . . . . . . . . . . . . . . . . . . 26
Data sheet status . . . . . . . . . . . . . . . . . . . . . . 30
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Disclaimers. . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Programmable angle sensor
Document identifier: KMA199E_1
Date of release: 18 October 2007
KMA199E
All rights reserved.

Related parts for KMA199E,115