4010A B&K Precision, 4010A Datasheet - Page 11

FUNCTION GENERATOR 2MHZ

4010A

Manufacturer Part Number
4010A
Description
FUNCTION GENERATOR 2MHZ
Manufacturer
B&K Precision
Type
Functionr
Datasheets

Specifications of 4010A

Includes
Cable
Frequency Band
0.2Hz ~ 2MHz (7 Ranges)
Display Type
No Display
Supply Voltage
120V/230V
Signal Types
Sine, Square, Triangle, Ramp, Pulse
Frequency
0.2 Hz to 2 MHz
Equipment Type
Function Generators
Bandwidth
2MHz
Modulation Type
FM
External Height
114mm
External Width
298mm
External Depth
264mm
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Rohs Compliant
No
Signal Generator Type
Function
Number Of Channels
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
BK4010A
6.
Remember that the output signal swing of the generator
is limited to ±10 volts open circuited or ±5 volts into 50
Ω, and applies to the combined peak-to-peak signal and
DC offset. Clipping occurs slightly above these levels.
Fig. 3 illustrates the various operating conditions
encountered when using the DC offset. If the desired
output signal is large or if a large DC offset is required,
an oscilloscope should be used to make sure that the
desired signal is obtained without undesirable clipping.
Figure 3. Use of DC OFFSET Control
OPERATING INSTRUCTIONS
11
CONSIDERATIONS
7. A superimposed DC component can be added to the output
l. Counterclockwise rotation of the FREQUENCY control
2. Clockwise rotation of the FREQUENCY control increases
3. When the dial is set to 1.0, the output frequency is one half
4. A more precise frequency setting may be achieved by
5. When outputting square waves or when using the TTL
signal by engaging the DC OFFSET switch (12) to enable
operation of the DC OFFSET control (5). Rotation of this
control adds a positive or negative DC component to the
output
independent of the OUTPUT LEVEL control and can be
varied by ±10 volts open circuited or ±5 volts into 50 Ω.
The DC Offset does not affect the TTL/CMOS output
jack. The effect of DC OFFSET is shown in Fig. 3.
decreases the output frequency to approximately one-tenth
of the maximum for the range selected (10:1). For
example,
FREQUENCY control is set to full counterclockwise (dial
setting of .2), the output frequency is approximately 2 kHz.
the output frequency. At the fully clockwise setting (dial
setting of 2.0), the output frequency will be equal to the
RANGE selection. That is, when the 20K range is selected
and the dial is set to 2.0, the output will be 20 kHz.
of the maximum for the range selected. When the 20K
range is selected and the dial is set to 1.0, the output will
be 10 kHz.
connecting an external frequency counter to the TTL or
output jack.
output, terminate the cable into 50 Ω to minimize ringing.
Also, keep cables as short as possible.
signal.
if
the
The
20K
DC
range
component
is
selected
introduced
and
the
is