FLUKE-289 Fluke Electronics, FLUKE-289 Datasheet - Page 87

DMM TRUE RMS 50000CNT W/BCKLGHT

FLUKE-289

Manufacturer Part Number
FLUKE-289
Description
DMM TRUE RMS 50000CNT W/BCKLGHT
Manufacturer
Fluke Electronics
Series
28xr
Type
Digital (DMM)r
Datasheet

Specifications of FLUKE-289

Includes
Battery, Clips, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
50000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, dB
Features
Data Logging, Hold, Memory, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
289
614-1062
Input Characteristics
Function
Function
[1]
[2]
50e
L
mV
G
F
L
K
e
Input is limited to the product of a V rms sinewave times frequency of 2 x 10
For circuits <0.5 A short circuit. 660V for high energy circuits.
Protection
Protection
1000 V
1000 V
1000 V
1000 V
1000 V
1000 V
1000 V
Overload
Overload
[2]
[2]
[2]
[2]
[1]
[1]
Input Impedance
10 M <100 pF >120 dB at dc, 50 Hz or 60 Hz
10 M <100 pF >120 dB at dc, 50 Hz or 60 Hz
10 M <100 pF
3.2 k <100 pF
5 V dc
20 V decreasing
to 2.5 V
5 V dc
Open Circuit
Test Voltage
(ac-coupled)
(ac-coupled)
To 500 k
550 mV
>60 dB, dc to 60 Hz
Full Scale Voltage
(1 k
Common Mode
Rejection Ratio
Not specified
3.1 V dc
500 mV
unbalance)
>5 or 50 nS
<5 V
7
V-Hz.
500
1 mA
100 A
5 k
Typical Short Circuit Current
>60 dB at 50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
Normal Mode Rejection
50 k
10 A
Not specified
10 mA
1 mA
500 k
1 A
Detailed Specifications
0.3 A
5 M
0.3 A
50 M
77