FLUKE-113 Fluke Electronics, FLUKE-113 Datasheet - Page 14

no-image

FLUKE-113

Manufacturer Part Number
FLUKE-113
Description
MULTIMETER UTILITY TRU-RMS 600V
Manufacturer
Fluke Electronics
Series
11xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-113

Includes
Battery, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
6000
Function
Voltage, Resistance, Capacitance
Functions, Extra
Continuity, Diode Test
Features
Backlight, Hold, Min/Max, Sleep
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Lead free / RoHS compliant by exemption
Other names
3078875
Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of
18 °C to 28 °C, with relative humidity at 0 % to 95 %.
are given as follows:
Function
Function
k Chek
R
E
s
Ω
[1]
[2]
[3]
[3]
Specifications are subject to change without notice.
[3]
[3]
[3]
[1,2]
All k Chek voltage ranges are specified from 60 counts to 100 % of
range. Because inputs below 60 counts are not specified, it is possible
and normal for this and other true-rms meters to display non-zero
readings when the test leads are disconnected from a circuit or are
shorted together.
Crest factor of ≤3 at 4000 counts, decreasing linearly to 1.5 at full scale.
After measuring voltage, a wait time of 1 minute is required to maintain
accuracy of ohms, capacitance, diode test, and continuity.
±([% of reading] + [number of least significant digits])
6.000 V
60.00 V
600.0 V
2.000V
600.0 Ω
6.000 kΩ
60.00 kΩ
1000 nF
10.00 μF
100.0 μF
9999 μF
Range
Range
0.001 V
0.01 V
0.1 V
0.1 Ω
0.001 kΩ
0.01 kΩ
1 nF
0.01 μF
0.1 μF
1 μF
Resolution
Resolution
0.001V
Note
DC, 45 to 500 Hz
Beeper on <20 Ω, off >250 Ω; detects
opens or shorts of 500 μs or longer
2.0 % +3
100 μF - 1000 μF: 1.9 % + 2
> 1000 μF: 5 % + 20
Accuracy specifications
Accuracy
Accuracy
2.0 % + 3
0.9 % + 2
0.9 % + 1
0.9 % + 1
1.9 % + 2
1.9 % + 2
1.9 % + 2
500 Hz to 1 kHz
4.0 % + 3