ACD-330T Amprobe, ACD-330T Datasheet - Page 36

no-image

ACD-330T

Manufacturer Part Number
ACD-330T
Description
DMM CLAMP-ON W/BACKLIGHT
Manufacturer
Amprobe
Type
Digital (DMM)r
Datasheet

Specifications of ACD-330T

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
4
Display Type
LCD, Bar Graph
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Display Count
-
Other names
2730749
Specified accuracy +/-40 digits for changes > 1 ms in duration.
• Overload protection: 1000Vrms AC;< 1000000 VxHz
• Overload protection: 600VRMS
• Overload protection: 600VRMS
• Instant continuity mode, built-in buzzer sounds when resistance is less than 10.0 .
(Maximum input for
specified accuracy
=10 x range or1000V)
1000A
Range
Range
100Hz
1kHz
Range
400A
Diode
400
4k
CURRENT (1ms PEAK HOLD)
FREQUENCY(AC coupling)
DIODECHECK
AUDIBLE CONTINUITYTEST
Diode
Range
RESISTANCE
INPUTRANGE
Range
1000A
1000V
400A
400V
FREQUENCYCOUNTERSENSITIVITY
Resolution
Resolution
0.1
1
1mV
Resolution
Resolution
0.01Hz
Resolution
0.1Hz
0.1A
1mV
1A
±(1%rdg+3dgt)
Accuracy
±(1.0%rdg+2dgt) approx. 1.65 mA
MINIMUM SENSITIVITY
Accuracy
built-in buzzer
sounds when
reading is
below approx.
100mV
±(0.2%rdg+4dgt)
Accuracy
(RMSSINEWAVE)
40 Hz-2 kHz
Accuracy
±(2%rdg+43dgt)
±(2%rdg+43dgt)
3A
30A
3V
30V
Max Test Voltage
32
Accuracy
1.25V
3.3V
approx. 1.65 mA
Test Current
Test Current
Minimum Input Frequency
Overload Protection
10Hz
600Vrms
Test Voltage
Test Voltage
<3.3V
<3.3V