... PY14QN(2) Rated time 3 min 5 min 10 min 30 min 60 min 3 h --- CSM_H3Y_DS_E_2_1 Mounting Surface/DIN-track Surface mounting mounting (with PCB terminals) (with socket) H3Y-2 H3Y-2-0 H3Y-4 (See note 3.) H3Y-4-0 (See note 3.) Wire-wrap terminal PC terminal PY08-02 PY14-02 Time setting range 0 min 0 min 0 min min min 0 --- 1 ...
Page 2
Ratings Item Rated supply voltage (See note 6.) 24, 100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz) (See note 1.), 12, 24, 48, 125, 100 to 110 VDC (See notes 2 and 3.) Operating voltage range ...
Page 3
Characteristics ±1% FS max. (0.5 s range: ±1%±10 ms max.) Accuracy of operating time ±10%± max. Setting error (see note 1) Reset time Min. power-opening time: 0.1 s max. (including halfway reset) Reset voltage 10% max. of ...
Page 4
Engineering Data H3Y-2, H3Y-2-0 250 VAC, cosφ VDC, cosφ Load current (A) Reference: A maximum current of 0.6 A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.2 A can be ...
Page 5
Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Timers H3Y-2 21.5 max. 6.4 (63.0) H3Y-2-0 21.5 max. (60.7) Mounting Holes Eight, 1.3-dia. holes H3Y-4 28 max. 6.3 (63.0) H3Y-4-0 28 max. 6.3 (60.7) Mounting Holes H3Y 28 ...
Page 6
Accessories (Order Separately) Use the PYF@A, PY@, PY@-02, or PY@QN(2) to mount the H3Y. When ordering any one of these sockets, replace “@” with “08” or “14.” Track Mounting/Front Connecting Sockets PYF08A Eight, M3 × 8 Two, 4.2 × ...
Page 7
... Note: With PY@QN(2), dimension * should read 20 max. and dimension ** 36.5 max. PY08-02, PY14-02 22 max. 0.3 29.5 25.5 max. max. 4.3 2.7 2 16.5 max. (Top View) (Top View) Terminal Arrangement ...
Page 8
... Socket Mounting Plates (t = 1.6) Applicable socket PY08, PY14, PY08QN(2), PY14QN(2) Note: PYP-18 may be cut to any desired length. PYP-1 Two, 3.4-dia. holes Relay Hold-down Clips Mounting Track PFP-100N/PFP-50N (see note 1) 1000 (500) (See note 2) Note: 1. Meets DIN EN50022 2. This dimension applies to PFP-50N. ...
Page 9
Installation ■ Connection H3Y-2, H3Y-2-0 Connect the DC power supply to terminals 13 and 14 according to the polarity marks. H3Y-4, H3Y-4-0 Connect the DC power supply to terminals 13 and 14 according to the polarity marks. H3Y 9 ...
Page 10
Safety Precautions Refer to Safety Precautions for All Timers. When selecting a control output, use the H3Y-2 for switching ON and OFF the power and the H3Y-4 for switching ON and OFF the minute load. The operating voltage will increase ...
Page 11
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...