AS6M-2Y2 IDEC, AS6M-2Y2 Datasheet - Page 30

no-image

AS6M-2Y2

Manufacturer Part Number
AS6M-2Y2
Description
Switch
Manufacturer
IDEC
Datasheet
• Turn off the power to A series control units before starting
• To avoid burning your hand, use the lamp holder tool when
30
Replacement of Lens and Marking Plate
• Removal
Remove the lens assembly (color lens, marking plate, lens holder,
and spring) by holding the color lens recesses with the Lens
Removal Tool (MT-101) and pulling it out. Remove the marking plate
by disengaging the latches between the color lens and lens holder.
The marking plate must be engraved on the front side as shown
below.
• Installation
Place the marking plate on the lens holder in the correct direction,
and press the color lens onto the lens holder to engage the latches.
Put the spring on the lens holder and insert the lens holder into the
housing in the correct direction.
• Installing Non-illuminated Button
Non-illuminated
illuminated units. Be sure to install the marking plate when replacing
the button.
Replacing the LED Lamp
• Removal
Use the lamp holder tool (OR-66) to remove lamps. Do not use
pliers.
• Installation
Use the lamp holder tool (OR-66) to install lamps. Note the correct
side of the tool for removal or installation.
Panel Mounting
When mounting the control units onto a panel, use the optional
locking ring wrench (MT-002) to tighten the locking ring. Do not use
pliers. Tightening torque must not exceed 0.78 N·m. Excessive
tightening will damage the locking ring.
ø12
installation, removal, wiring, maintenance, and inspection of the
control units. Failure to turn power off may cause electrical shocks
or fire hazard.
replacing lamps.
Safety Precautions
Operating Instructions
A2
Color Lens
For removing lamps
pushbuttons
Series
OR-66 (ø8, ø10, ø12 series)
Engraving
Area
Lamp Holder Tool
Marking
Plate
Latches
Miniature Control Units
contain
Lens Holder
For installing lamps
a
marking
plate
like
• For wiring, use wires of a proper gauge to meet the voltage and
Wiring
Solder the terminal at 350°C within 3 seconds using a 60W
soldering iron. Sn-Ag-Cu type is recommended when using lead-
free solder. When soldering, do not touch the control unit with the
soldering iron. Also ensure that no tensile force is applied to the
terminal. Do not bend the terminal or apply excessive force to the
terminal.
Use non-corrosive rosin flux.
Installing the Socket
Install the socket on the control unit with the TOP markings on the
control unit and the socket placed in the same direction.
Operating Voltage of LED Lamps
The operating voltage is measured at complete DC. When using a
pulsating voltage such as a full-wave rectification voltage, keep
peak currents within the forward current If. Peak currents exceeding
the If may shorten the LED lamp life.
Other Notes
• Close Proximity Mounting
When mounting pilot lights or illuminated pushbuttons collectively or
lighting them continuously, heat may cause the ambient
temperature to rise above the rated operating temperature. When
the mounting panel is not made of metal or when the control units
are mounted in an enclosed panel, provide for ventilation or lower
the operating voltage.
• Replacement of Buttons (Illuminated/Non-illuminated)
Do not replace buttons of maintained action units while the button is
in the locked position. Replacing the button in the locked position
may damage the internal mechanism. Be sure to release the button
before replacing.
• Operating and Storage Environment
1. Make sure that the operating/storage temperature and humidity
2. Do not use enclosed type units (IP40) in an environment subject
• Microswitch Contacts
Do not connect NO and NC contacts of the microswitch to different
voltages or different power sources to prevent a dead short-circuit.
• IP65 Type Units
IP65 type units are evaluated by conventional cutting and cooling
oils, and can not be used with some special oils. Contact IDEC for
resistance against special oils.
current requirements. Failure to tighten terminal screws may
cause overheating and create a fire hazard.
are within the ratings.
to oil, water or dust accumulation. In such an area, use the
waterproof/oiltight units (IP65).
(06/11/10)

Related parts for AS6M-2Y2