UM-FA-11A BANNER ENGINEERING, UM-FA-11A Datasheet

no-image

UM-FA-11A

Manufacturer Part Number
UM-FA-11A
Description
SAFETY RELAY UM-FA-11A 22.5MM UNVRSL MODULE CNTCT/SLD ST IN 2NO & 1NC OU
Manufacturer
BANNER ENGINEERING
Datasheet
Original Instructions
This Safety Module is not a point-of-operation guarding device, as defined by OSHA regulations. It is necessary
to install point-of-operation guarding devices, such as safety light curtains and/or hard guards, to protect personnel
from hazardous machinery. Failure to install point-of-operation guards on hazardous machinery can result
in a dangerous condition which could lead to serious injury or death.
WARNING . . . Not a Point-of-Operation Guarding Device
Emergency
Stop
Devices
29YL
UM-FA-9A
UM-FA-11A
Monitors a wide variety of safety and non-safety input devices:
The safety inputs can monitor:
UM-FA-9A: Three normally open (N.O.) output switching channels for
connection to control-reliable power interrupt circuits
UM-FA-11A: Two normally open (N.O.) and one normally closed (N.C.)
output switching channels for connection to control-reliable power interrupt
circuits
Automatic reset or monitored manual reset, depending on hookup
Design complies with standards ANSI B11.19, UL991, ISO 13850
(EN418), and ISO 13849-1 (EN954-1) (Safety Category 4)
Safety Integrity Level (SIL) 3 (IEC 61508/62061)
Performance level (PL) e (ISO 13849-1)
For use in functional stop category 0 applications per ANSI NFPA 79 and
IEC/EN 60204-1
Plug-in terminal blocks
24V ac/dc operation
Optical-based safeguarding devices, such as Safety Laser Scanners
Positive-opening safety switches used for guard interlocking
Emergency-stop devices, such as palm buttons and rope/cable pulls
Standard sensors for non-safety applications, such as photoelectric
monitoring position or end-of-travel.
+24V dc solid-state (PNP) outputs in single-channel or dual-channel
hookup,
+24V dc source that is switched by hard/relay contacts in single-channel
or dual-channel hookup, or
Hard/relay contacts in a dual-channel hookup using terminals S11-S12
and S21-S22
UM-FA-..A Series Universal Input Safety
Modules
For 24V ac/dc operation, solid-state or relay inputs
Models
Output Switching Channels
3 normally open (N.O.)
2 normally open (N.O.), and
1 normally closed (N.C.)
Safety Output Contact
Rating
6A
7A
0 141249 9

Related parts for UM-FA-11A

UM-FA-11A Summary of contents

Page 1

... S21-S22 UM-FA-9A: Three normally open (N.O.) output switching channels for connection to control-reliable power interrupt circuits UM-FA-11A: Two normally open (N.O.) and one normally closed (N.C.) output switching channels for connection to control-reliable power interrupt circuits Automatic reset or monitored manual reset, depending on hookup Design complies with standards ANSI B11 ...

Page 2

... Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and maintenance instructions. Please direct any questions regarding the use or installation of this product to the factory applications department at the telephone numbers or address shown on back cover. ...

Page 3

... An important concept within the category requirements of ISO 13849-1 is the "probability of the occurrence of the failure," which can be decreased using a technique termed "fault exclusion." The rationale assumes that the possibility of certain well-defined failure(s) can be reduced to a point where the resulting fault(s) can be, for the most part, disregarded-that is, " ...

Page 4

... While only three applications are listed in this document, the Module can monitor a variety of devices as long as the input requirements are complied with (see Electrical Installation and Specifications). The UM-FA-..A Module does not have 500 ms simultaneity between inputs and thus can not be used for monitoring a two-hand control ...

Page 5

... Interlocked Guards (Gates): The safety inputs can be interfaced with positive-opening safety switches to monitor the position of an interlock guard or gate. Each switch must provide electrically isolated contacts: at minimum, one normally closed (N.C.) contact from each individually mounted switch. The contacts must be of "positive-opening" ...

Page 6

... Hard/relay contacts in a dual-channel hookup configuration using terminals S11-S12 and S21-S22. The UM Safety Module must be configured (via DIP switch) for the appropriate hookup in order to operate properly. When using devices with redundant solid-state safety outputs (such as the AG4 Safety Laser Scanner OSSDs) or redundant hard contacts switching a +24V dc source, both the DIP switches must be set to the " ...

Page 7

... This circuit can detect a short circuit between channels or to another source of power minimum, when the device is actuated. The solid-state dual-channel hookup configuration can not detect short circuits between input channels or to secondary sources of +24V dc ...

Page 8

... Safety Module terminals S31 and S32. 8 Banner Engineering Corp. - Minneapolis, MN USA - Tel: 763.544.3164 UM-FA-9A/-11A Universal Module P/N 141249 rev. C ...

Page 9

... UM-FA-9A/-11A Universal Module Auto Reset +24V ac/dc UM-FA-..A A1 S11 DIP Switch S21 Configuration S22 S12 Devices with Devices with relay output positive-opening contacts contacts Figure 4: Dual-channel hookup configuration, devices with hard contacts Auto Reset +24V dc UM-FA-..A A1 +24V dc 0V ...

Page 10

... See Interfacing MSCs WARNING 0V dc +24V ac/ +24V dc MSC1 MSC2 MSC3 MSC Monitor Contacts or Jumper Banner Engineering Corp. - Minneapolis, MN USA - Tel: 763.544.3164 UM-FA-9A/-11A Universal Module Manual Reset 0V Devices with positive- UM-FA-..A opening contacts A2 A1 MSC1 MSC2 MSC3 S33 S11 DIP Switch (No S34 ...

Page 11

... Failure could result in serious bodily injury or death. Automatic Reset Mode The Safety Module may be used also with automatic reset MSC-monitor contacts are monitored, a jumper must be installed between terminals S33 and S34 (see Figures and 7). The Safety Module will reset (and the outputs energize) as soon as the inputs return (or "closed-contact") state. ...

Page 12

... NOTE: The minimum amount of time required for the Module STOP or OFF condition is 250 ms. This “recovery time” (OFF-state) is required for the internal circuitry of the Safety Module to normalize, allowing a reliable reset to occur. A lockout will occur if the Module is cycled too quickly. To clear the lockout, re-cycle the Module, meeting the minimum OFF time requirements ...

Page 13

... UM-FA-9A/-11A Universal Module CAUTION . . . Disconnect Power Prior to Checkout Before performing the initial checkout procedure, make certain all power is disconnected from the machine to be controlled. Dangerous voltages may be present along the Safety Module wiring barriers whenever power to the machine control elements is ON. Exercise extreme caution whenever machine control power is or may be present. ...

Page 14

... Do not attempt any repairs to the Safety Module. It contains no field-replaceable components. Return it to the factory for warranty repair or replacement. Contact Banner Factory Application Engineering at the address or the numbers listed on the back page. They will attempt to troubleshoot the system from your description of the problem. If they conclude that a component is defective, they will issue a return merchandise authorization (RMA) number for your paperwork, and give you the proper shipping address ...

Page 15

... Output Model UM-FA-9A: 3 normally open (N.O.) output channels Configuration Model UM-FA-11A: 2 normally open (N.O.) output channels and 1 normally closed (N.C.) auxiliary output channel Each normally open output channel is a series connection of contacts from two forced-guided (mechanically linked) relays, K1-K2.The normally closed Aux. output channel of the UM-FA-11A is a parallel connection of contacts from two forced-guided relays, K1-K2. Contacts: AgNi, 5 µ ...

Page 16

... NEMA 3 (IEC IP54), or better. Vibration 0.35 mm displacement per IEC 60068-2-6 Resistance Operating Temperature: 0° to +50°C (+32° to 122°F) Conditions Max. Relative Humidity: 90% @ +50°C (non-condensing) Design Standards Cat per EN ISO 13849-1; SIL 3 per IEC 61508 and IEC 62061 Certifications Emergency Stop Devices ...

Page 17

... UM-FA-9A/-11A Universal Module Figure 9: Dimensions P/N 141249 rev. C Figure 10: Product label (model UM-FA-9A shown) Banner Engineering Corp. - Minneapolis, MN USA - Tel: 763.544.3164 S21 S33 S11 Power UM-FA- S22 S34 S12 17 ...

Page 18

... Banner Enginering Corp. 9714 Tenth Avenue North Minneapolis, MN 55441-5019 USA We herewith declare that UM-FA-9A and UM-FA-11A Universal Safety Modules for industrial control are in conformity with the provisions of the Machinery Directive (Directive 98/37/EEC), and all essential Health and Safety Requirements have been met. ...

Related keywords