H7CX-AS-N AC100-240 Omron, H7CX-AS-N AC100-240 Datasheet - Page 13

ScrwTerm,Tr.out,12VDC PS,6digt

H7CX-AS-N AC100-240

Manufacturer Part Number
H7CX-AS-N AC100-240
Description
ScrwTerm,Tr.out,12VDC PS,6digt
Manufacturer
Omron
Datasheet

Specifications of H7CX-AS-N AC100-240

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Transistor
Voltage - Supply
100 V ~ 240 VAC
Display Type
LCD Backlit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CXASNAC100240
Z3045
Connection Sockets
Front Connecting Socket
Note: Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals.
Back-connecting Sockets
Note: A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction.
Terminal Covers for P3GA-11 Back-connecting Socket
Note: The Terminal Cover can be used with a Back-mounting Socket (P3GA-11) to create a finger-safe construction.
Model
P2CF-11
P2CF-11-E
(Finger-safe Type)
Model
P3GA-11
Model
Y92A-48G
Eleven, M3.5
Eleven, M3.5
34
Two, 4.5-dia. holes
Two, 4.5-dia. holes
Y92A-48G
45
Twelve, 6.4-dia. holes
7.5 sems screws
47.4
7.5 set screws
UP
P C
10
8
9
27 dia.
11
7
45
P2CF-11-E
10A250VAC
RESISTIVE
47.7 47.7
50 max.
16.5
40
Dimensions
Dimensions
Dimensions
50 max.
0.2
24.6
6
1
4
3
27.6
5
2
7.8
4.5
7.8
4
70 max.
48
4
16.3
70 max.
48
1.2
3
5
6.2
25.6
3
31.2 max.
30
31.2 max.
4.5
35.4
4
and internal connections
and internal connections
Terminal arrangement
Terminal arrangement
10 11
(Bottom View)
8
9
(Top View)
4
3
5
2
7
6
1
11
7
6
1
10
8
9
5
4
3
2
Note: The Socket can
H7CX-A@-N
Two, M4 or 4.5-dia. holes
Mounting hole
also be mounted
to DIN track.
dimensions
40
0.2
13