A165E-S-01 Omron, A165E-S-01 Datasheet - Page 9

E-stop,non-lighted,1NC,30diamt

A165E-S-01

Manufacturer Part Number
A165E-S-01
Description
E-stop,non-lighted,1NC,30diamt
Manufacturer
Omron
Series
A16r
Type
Emergency Stopr
Datasheets

Specifications of A165E-S-01

Circuit
SPST-NC
Switch Function
On-Off
Contact Rating @ Voltage
5A @ 125VAC
Actuator Type
Round Button
Mounting Type
Panel Mount
Termination Style
Solder, Quick Connect - .110" (2.8mm)
Control Type
Emergency Stop
Contact Form
SPST - NC
Contact Rating
5 Amps at 125 VoltsAC
Illuminated
N
Contact Configuration
SPST-NC
Switch Operation
Pushlock Turn Reset
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Current Max
5A
Actuator Style
Round
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Illumination Type, Color
-
Illumination Voltage (nominal)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
A165ES01
Z1427
Installation
Mounting to the Panel
After installing the Operation Unit, snap in the Switch from the back of the panel.
• Attach rubber packing or the Yellow Plate
• Adjust the slits on the hole of rubber
• Rubber packing is not necessary when the
• Tighten the nut to the torque of 0.29 to
• Casing should be installed with its
• Align the lock ring to the groove of the
• Snap on the Switch to the Operation Unit.
• Make sure that the Switch has the correct orientation when snapping it onto the
• When mounting the Lamp, make sure it is facing the direction shown in the
onto the Switch from its terminal side.
Insert the Switch into the panel from the
front. Install the lock ring and mounting nut
from the terminal side and tighten.
packing and Yellow Plate to the protruding
part of the Unit.
Yellow Plate is used.
0.49 N·m.
protruding part adjusted to the slit of the
panel hole.
casing so that the edge is drawn to the
panel side.
Operation Unit. Align the white dot on the Operation Unit with the guide groove
on the side of the Switch marked with an “L” as shown below, and push the
Switch into the Operation Unit until it clicks into place. Confirm that the Switch is
securely in place before using.
following diagram. Insert the Lamp while matching the protruding part of the
Lamp and the small guides on the outer surface of the casing.
Protruding part
http://www.ia.omron.com/
(4) Installing the LED Lamp
(2) Mounting the Switch
White dot
Wide guide
Lock hole
Guide groove
Narrow guide
Cutout
Lock
(1) Installing the Operation Unit
L marking
Mounting nut
Rubber packing
(included with the
product) or Yellow
Plate (sold separately)
• Insert the prongs of the A16Z-5080 Extractor between the Switch and the
Lock ring
Operation Unit, grip the Switch, and pull to remove.
Panel
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
(3) Removing the Switch
Extractor (A16Z-5080)
Rubber packing or Yellow Plate (sold separately)
Panel
Edge
Mounting nut
Lock ring
A165E
9

Related parts for A165E-S-01