CS1W-AD161 Omron, CS1W-AD161 Datasheet - Page 18

no-image

CS1W-AD161

Manufacturer Part Number
CS1W-AD161
Description
CS1 16 Pt Analog Inp Conn Type
Manufacturer
Omron
Datasheet

Specifications of CS1W-AD161

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Analog I/O Units
Overview
A wide range of 25 I/O Units, including 16 Isolated-type Units, covers
almost all typical applications. Also featuring high-speed (10 ms) and
high-resolution (1/64,000) types, this line-up meets a diverse array of
potential uses, from data logging to high-speed measurement control.
Overview of Process Analog I/O Units
CS1W-PTS11
Isolated-type
Thermocouple
Input Unit (high-
resolution)
Isolated-type
Resistance
Thermometer
Input Unit (high-
resolution)
Isolated-type
DC Input Unit
(high-resolu-
tion)
Isolated-type
Thermocouple
Input Unit (eco-
nomical type)
Isolated-type
Resistance
Thermometer
Input Unit (eco-
nomical type)
Isolated-type
DC Input Unit
(economical
type)
Isolated-type
Thermocouple
Input Unit
Analog I/O Units
Name
CS1W-PTS11
CS1W-PTS12
CS1W-PDC11
CS1W-PTS51
CS1W-PTS55
CS1W-PTS52
CS1W-PTS56
CS1W-PDC55
CS1W-PTS01-V1 4 inputs All inputs
Model
CS1W-PTS12
4 inputs All inputs
4 inputs All inputs
4 inputs All inputs
4 inputs All inputs
8 inputs
4 inputs All inputs
8 inputs
8 inputs All inputs
Number
of I/O
are isolated.
are isolated.
are isolated.
are isolated.
are isolated.
are isolated.
are isolated.
isolation
Field I/O
CS1W-AD161
B, E, J, K, L, N, R,
S, T, U, WRe5-26,
PLII, 100 mV
Pt100
IEC), JPt100 ,
Pt50 , Ni100
4 to 20 mA, 0 to
20 mA, 0 to 10 V,
V, 1 to 5 V,
0 to 1.25 V,
R, S, K, J, T, L, B Centigrade Selected
JPt100, Pt100
(JIS IEC)
4 to 20 mA, 0 to
10 V,
0 to 5 V, 1 to 5 V
B, E, J, K, N, R, S,
T
Variable range:
10 V, 0 to 5 V, 5
1.25 V
80 mV DC
I/O type
(JIS,
Standard accuracy: ±0.05% of F.S.
Temperature coefficient: ±0.01%/°C
Resolution: 1/64,000
Conversion period: 20 ms/4 pts,
Standard accuracy: ±0.05% of F.S. or
±0.1, whichever is larger
Temperature coefficient: 0.009%/ C
Resolution: 1/64,000
Conversion period: 20 ms/4 points,
Standard accuracy: ±0.05% of F.S.
Temperature coefficient: 0.008%/ C
Resolution: 1/64,000
Conversion period: 20 ms/4 pts,
Total accuracy: ±0.3% of PV or ±1°C
whichever is larger, ±1 digit max.
Conversion period: 250 ms/Unit
Centigrade Selected
Total accuracy:
±0.3% of PV or ±0.8°C,
whichever larger, ±1 digit max.
Conversion period: 250 ms/Unit
Standard accuracy: ±0.3% of F.S.
Resolution: 1/16,000
Conversion period:
250 ms/8 inputs
Standard accuracy: 0.1%
Temp. coefficient: 0.015%/ C
Resolution: 1/4,096
Conversion cycle: 150 ms/4 pts
Features
• Dramatic reductions in installation cost, space, and set-up steps are
• Process value alarms and rate-of-change calculations can be exe-
• Rate-of-change limits and high/low output limits calculated for analog
• Peak/bottom hold and top/valley hold functions can be used for pro-
• Zero point and span can be adjusted for any specified range, and
• Changes exceeding a set threshold can be counted, and analog
• Reduced wiring with MIL connectors (CS1W-AD161 only).
attained by eliminating the need for external setters and converters.
cuted from temperature and analog inputs.
output.
cess values (CS1W-P@@1@ only).
adjustment days and times can be automatically saved. The adjust-
ment deadline and adjustment deadline expiration notice can also be
set and notification given (CS1W-P@@1@ only).
input values can be integrated (CS1W-P@@1@ only).
XW2D-34G6 Connector-Terminal Block Conversion Unit can be
used.
Main specifications
(See note.)
10 ms/2 pts
10 ms/2 pts
10 ms/2 pts
Output scaling (±32,000)
Process value alarms (HH, H, L, LL)
Rate-of-change calculation and alarm In-
put disconnection alarm
Top/bottom/valley hold
Zero/span adjustment for any specified
rang
Output scaling (±32,000)
Process value alarms (HH, H, L, LL)
Rate-of-change calculation and alarm In-
put disconnection alarm
Top/bottom/valley hold
Zero/span adjustment for any specified
range
Output scaling (±32,000)
Process value alarms (HH, H, L, LL)
Rate-of-change calculation and alarm In-
put disconnection alarm
Top/bottom/valley hold
Zero/span adjustment for any specified
range
Process value alarms (H, L)
Input disconnection detection
Process value alarms (H, L)
Input disconnection detection
Process value alarms (H, L)
Input disconnection alarm
Variable range setting
Scaling ( 32,000)
Process value alarms (HH, H, L, LL)
Rate-of-change calculation and alarm
Input disconnection detection
Main functions
Overview