CS1W-AD161 Omron, CS1W-AD161 Datasheet - Page 5

no-image

CS1W-AD161

Manufacturer Part Number
CS1W-AD161
Description
CS1 16 Pt Analog Inp Conn Type
Manufacturer
Omron
Datasheet

Specifications of CS1W-AD161

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
8
The Smart Products that Configure OMRON Process Control
Process Analog I/O Units
SYSMAC CS1D-series Duplex PLCs
Loop Control Boards (LCBs) and Loop Control Units (LCUs)
Loop Control Boards (LCBs) and Loop Control Units (LCUs)
Packed with complete DCS
functionality, the LCBs/LCUs are
programmed with function blocks
designed specifically for process
control. By combining function blocks,
a wide array of control methods,
from basic PID control to cascade and
feed-forward control can be easily
configured.
The LCB/LCU is used in combination
with I/O Units to perform I/O
operations.
Process Analog I/O Units
These Analog I/O Units provide the
functionality of isolators, power
supplies, signal converters, and other
devices. The built-in functions, such as
measurement value alarms, rate-of-
change calculations, and square roots,
have enabled major savings in cost and
space compared with previous systems.
High-resolution Models and 8-point
Input Models are also available. By
combining the Units,
logging/monitoring systems can be
constructed, or the Units can be used
together with LCBs/LCUs to construct
complete process control systems.
Parameters can be easily displayed and
set in an easy-to-understand form
without special tools.
SYSMAC CS1D-series Duplex PLCs
Process control system redundancy is
easily achieved by mounting
Process-control CPU Units to the
SYSMAC CS1D system. A duplex
system can greatly reduce risk in
chemical plants, ship boiler systems,
semiconductor utilities, or anywhere
reliability is demanded.
Temperature
Example: Cascade Control
(Heating/Cooling)
Analog
Input Unit
Replace Units without Stopping the System.
Existing DCS's, PLCs, etc.
Active
Analog
Output Unit
Cooling
water
Drain
PV1
PV2
Loop Control
Unit/Board
Temperature
Split
conversion
PID1
PID2
Heat
exchange
Standby
MV2
Active
MV1
RSP1
Process I/O Units
Steam
With Function Blocks:
Isolated-type
Ai4 Terminal
Problem
corrected
Y1
Y2
Y3
Y4
Standby
PV
PVE
RSP
MIE
MVE
PV
PVE
RSP
MIE
MVE
Basic PID
Basic PID
PID1
PID2
I/O tables
SP
Y1
MV
SP
Y1
MV
Parameter settings
X1
Split
Converter
Active
Duplex operation
resumed.
Y1
Y2
Isolated-type
Ao4 Terminal
X1
X2
X3
X4
Y1
Y2
Y3
Y4
CX-One
CX-One
CX-Process Tool
CX-Process Tool
The required number of engineering steps is reduced by software that
enables analog control programming by combining function blocks and
easy connection to HMI devices.
The CX-One is an integrated software package that
includes the CX-Programmer PLC Support Software and
CX-Process Loop Controller Support Software, as well as
the CX-Designer PT Support Software. The CX-One
provides inter-software information and settings
inheritance for complete system-level support. Even
advanced parameters from CPU Unit to CPU Bus Unit
parameters through FA network startup can be easily set
without relying on user manuals.
Program graphically by pasting function blocks for PID
control, square root calculations, or other functions in a
window and then connect them with the mouse. Multiple
function blocks can be grouped together to define a
single user-defined function block. Function blocks can
also be used in sequence tables and step ladders for
sequence control programming.
Engineering is simplified by a host of debugging
functions that help in setting up the program.
CX-Process Monitor Plus
CX-Process Monitor Plus
This Windows-based utility is used to download function
block data from Loop Controllers and to monitor the
system with control windows (images of the on-site
functions), trend windows, graphic windows,
annunciator windows, and more. Window configurations
can be easily produced by simply selecting the desired
tags.
Operation and Debugging
ITEM lists for individual function blocks can be
monitored or settings can be changed.
Parameters can be easily monitored or changed on
tuning windows (up to 4 windows can be started
simultaneously).
Tuning data can be saved in CSV format.
Individual function blocks can be added or deleted
during operation.
Connection, tag, and comment data can be downloaded
to or uploaded from a Memory Card in a Loop Control
Board (see note) or CPU Unit.
Note: Except for CS1D Process-control CPU Units.
Monitoring
Integrated Package Tool
Programming
Overview window
Block connection diagrams
Connection map
Trend window
Operation check
ITEM list
Network Support Software:
CX-Integrator
Sequence table
Tool tuning
9

Related parts for CS1W-AD161