D4B-1171N Omron, D4B-1171N Datasheet - Page 4

LSW,PG13.5,SNAP,TOP PLNGR

D4B-1171N

Manufacturer Part Number
D4B-1171N
Description
LSW,PG13.5,SNAP,TOP PLNGR
Manufacturer
Omron
Series
D4B-Nr
Datasheets

Specifications of D4B-1171N

Contact Form
NO / NC
Contact Rating
2 Amps
Actuator
Plunger, Top Roller
Operating Force
18.63 N
Termination Style
Screw
Actuator Style
Top Roller Plunger
Operating Force Max
18.63N
Contact Voltage Ac Max
400V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
10A
Circuit
DPST (1-NO, 1-NC)
Switch Function
On-Mom, Off-Mom
Contact Rating @ Voltage
10A @ 120VAC
Actuator Type
Roller Plunger
Mounting Type
Chassis Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
J UL/CSA: (UL508, CSA C22.2 NO. 14)
A600
Q150
Rating Codes for DC Control-Circuit Contacts
J CHARACTERISTICS
Note: 1. The above values are for initial operation.
Rated voltage
120 VAC
240 VAC
480 VAC
600 VAC
Thermal continuous
test current
test current,
amperes
2.5
Item
Life expectancy
(
(see note 2)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (U
Counter electromotive voltage at switching 1,500 VAC max. (EN60947-5-1)
Operating environmental pollution level
Conditional short-circuit current
Conventional enclosed thermal current
(I
Electric shock protection class
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Degree of protection
Weight
the
)
Between terminals of same polarity
Between terminals of different polarity
Between current-carrying metal parts
and ground
Between each terminal and
non-current-carrying parts
2. The life expectancy is for an ambient temperature of 5°C to 35°C and ambient humidity of 40% to 70%. For further conditions,
3. The values in this table are for an ambient temperature of 5°C to 35°C and ambient humidity of 40% to 70%. For further condi-
p
consult your OMRON sales representative.
tions, consult your OMRON sales representative.
2)
g
y
Maximum make or break current, amperes
125 Volt
0.55
Carry current
C
10 A
Mechanical
Electrical
y
i
)
Snap-action
30,000,000 operations min.
500,000 operations min. (at a 250 VAC, 10-A resistive load)
1 mm/s to 0.5 m/s
Mechanical: 120 operations/min
Electrical:
50/60 Hz
100 MΩ min. (at 500 VDC) between terminals of the same polarity and between each
terminal and non-current-carrying part
25 mΩ max. (initial value)
U
U
U
600 VAC (EN60947-5-1)
3 (EN60947-5-1)
100 A (EN60947-5-1)
20 A (EN60947-5-1)
Class I (with grounding terminal)
Malfunction: 10 to 55 Hz, 0.75 mm single amplitude
Destruction: 1,000 m/s
Malfunction:300 m/s
Operating: --40°C to 80°C, with no icing (--25°C to 80°C for the flexible-rod type)
Operating: 95% max.
IP67 (EN60947-5-1)
Approx. 250 g
---
Current
Make
60 A
30 A
15 A
12 A
250 Volt
imp
imp
imp
2.5 kV
4 kV
4 kV
30 operations/min
2
min.
2
5
Break
6 A
3 A
1.5 A
1.2 A
301 to 600 Volt
min.
Slow-action
10,000,000 operations min.
U
U
U
U
Volt-amperes
Make
7,200 VA
Maximum make or break volt-amperes at
300 volts or less
300 volts or less
69
imp
imp
imp
imp
4 kV
4 kV
4 kV
4 kV
Break
720 VA
D4B-N

Related parts for D4B-1171N