DCN4-BR4D Omron, DCN4-BR4D Datasheet - Page 64
DCN4-BR4D
Manufacturer Part Number
DCN4-BR4D
Description
Thin Cable-Flat Cable Conv Con
Manufacturer
Omron
Datasheet
1.XW4B-05C4-TF-D.pdf
(166 pages)
Specifications of DCN4-BR4D
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 64 of 166
- Download datasheet (4Mb)
Minimizing Effects of a
Noisy Ground
2-2-11 Allocating Node Numbers
2-3
2-3-1
Available Cables
Cables, Connectors, and Related Devices
Thick Cable
Thin Cable
Cable
Cables, Connectors, and Related Devices
Communications Cables
Note
just that power supply’s to the shield wire and ground it. Do not connect the
shield wire at any other point.
1. Do not ground the shield wire at more than one point in the network.
2. Always use a separate ground. Never use the same ground that is used for
3. If a good ground of 100 Ω or less is not available, do not connect the com-
When the ground is identified as a source of noise in the network, disconnect
the DeviceNet shield wire to isolate it from the ground. If this step does not
stop noise from entering the network, do not ground the communications
power supply’s FG terminal.
Node numbers do not have to reflect the physical position of the nodes in the
network. It is possible to allocate node numbers randomly. It is also accept-
able to skip node numbers. While node numbers can be allocated randomly,
we recommend following a pattern when allocating node numbers. For exam-
ple, set the Master as node 63, the Slaves as nodes 1 through 62, and the
Configurator as node 0.
In a DeviceNet system, use DeviceNet cables that conforms to DeviceNet
specifications. The cable characteristics affect DeviceNet communications, so
cable that is not within DeviceNet specifications cannot be used. Always use
the specified DeviceNet cables.
There are two kinds of Special Thin/Thick Cable: Thick Cable and Thin Cable.
Thin Cable is used for the cables with attached shielded connectors.
Appearance
Ground the network at one point and one point only.
inverters or other drive system devices.
munication power supply’s FG and V- terminals because the ground may
introduce noise into the network.
DCA2-5C10
DCA1-5C10
Model
Outer diameter: 11.6 mm
Length: 100 m (See note.)
Outer diameter: 7 mm
Length: 100 m (See note.)
Specifications
Section 2-3
43
Related parts for DCN4-BR4D
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Std. Flat Cbl Branch Line Pres
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Multi-Wiring Connector
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Terminal Block Adaptor
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Std. Flat Cbl Conn Terminating
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Std. Flat Cbl Trunk Line Press
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Cabl PwrSupTrmBlk W/ TrmResist
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
DeviceNet Flat Cable Connector
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
NonUL Multidrop Flat Connector
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: