E3C-S20LW Omron, E3C-S20LW Datasheet - Page 11

EMITTER COMPONENT OF E3C-S20W

E3C-S20LW

Manufacturer Part Number
E3C-S20LW
Description
EMITTER COMPONENT OF E3C-S20W
Manufacturer
Omron
Series
E3Cr
Datasheet

Specifications of E3C-S20LW

Sensing Distance
7.874" (200mm)
Sensing Method
Through-Beam
Mounting Type
Bracket Mount
Package / Case
Module, Pre-Wired
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Voltage - Supply
-
Response Time
-
Output Configuration
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E3CS20LW

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3C-S20LW
Manufacturer:
VS
Quantity:
18 970
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the product in atmospheres or environments that exceed
product ratings.
● Wiring
Connection of E3C-JC4P Amplifier Unit and Sensor
Always run the shielded wires of the Emitter and Receiver separately.
Also, route the sensor cable along the cable grooves of the cover and
sensor and fix it with the cover.
Connection Socket
The standard socket is the PF113A for the E3C-A and -C, and the
PYF08A, PYF08M or PY08 for the E3C-GE4. Avoid using any other
sockets since they may not satisfy the characteristics. (There will be
no problem when the STABILITY indicator turns ON)
● Wiring
Extension Cable
• The extension distance of the sensor connection cable should be
• The strip-off length of the core in the connection cable should be 20
• Use independent shielded wires for the Emitter and Receiver.
within 10 m.
mm max. on the Receiver side and 50 mm max. on the Emitter side,
and the core should be as short as possible. Avoid using the joint
terminal and connector.
Using a common shielded wire can cause a malfunction.
Receiver
Emitter
Amplifier Units
Sensor Units
Precautions for Correct Use
(Shield) Red
White (Shield)
20 mm max.
WARNING
Socket
Extension Cable
Through-beam
Reflective model
● Others
When the E3C is used in a place where high-frequency noise will be
generated, e.g. ultrasonic welder, grounding the 0-V terminal (on the
shield side of the connection cable) of the Receiver may avoid a
malfunction caused by induction.
Model
E3C-S10
E3C-1
E3C-2
E3C-S50
E3C-S20W
E3C-S30T
E3C-S30W
Model
E3C-DS10
E3C-DS10T
E3C-VS1G
E3C-VS3R
E3C-LS3R
E3C-DS5W
E3C-VS7R
E3C-VM35R
Cable
Cable
2.4 dia.
Polyethylene insulation shield
Round cable
Vinyl insulation shield round cable
Vinyl insulation shield round cable
(robot cable)
Vinyl insulation shielded parallel ca-
ble
Vinyl insulation shielded parallel ca-
ble
2.4
1.7 dia.
1.8 dia.
12-conductor, 0.18 dia.
30-conductor, 0.08 dia.
12-conductor, 0.18 dia.
7-conductor, 0.18 dia.
12-conductor, 0.18 dia.
Specified cable
Specified cable
4.3
Shield
White (polyethylene)
Sheath
Shield
Polyethylene
Conductor
Sheath
Shield
Polyethylene
Conductor
Sheath
Shield
Polyethylene
Conductor
Conductor
Sheath
Internal
sheath
Shield
Polyethylene
1-conductor shield/
vinyl wire, conduc-
tor cross section:
0.3 mm
1-conductor shield/
vinyl wire, conduc-
tor cross section:
0.3 mm
When there is no1-
conductor shielded,
vinyl cable (parallel
wire), use two 1-
conductor shielded,
vinyl wires.
When there is no1-
conductor shielded,
vinyl cable (parallel
wire), use two 1-
conductor shielded,
vinyl wires.
Gray (vinyl sheath)
Replacement
Replacement
cable
cable
2
2
min.
min.
Shield
E3C
White
(vinyl)
11