F150-M05L Omron, F150-M05L Datasheet - Page 7

no-image

F150-M05L

Manufacturer Part Number
F150-M05L
Description
5.5Panel Mnt. Clr LCD Monitor
Manufacturer
Omron
Datasheets

Specifications of F150-M05L

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Rating/performance
Sensor: Z300-S10/Z300-S5/Z300-S60
*1. For Class 2 types, please inquire.
*2. Defined at 1/e2 (13.5%) of the central light intensity. If there is stray light outside of the defined area and the reflectance of the light around the work is higher than
*3. The error with respect to the ideal straight line of displacement output during measurement of our standard while aluminum ceramic. The linearity may vary de-
*4. The converted displacement value of peak-to-peak displacement output (when our standard aluminum ceramic is measured). In an electromagnetic field, resolution
*5. Using an average measurement count of 64 times with the Z300-VC10V3.
*6. Using an average measurement count of 512 times with the Z300-VC10V3.
*7. Measured value when set to high-speed mode.
*8. Value when the distance between the sensor and the object (white aluminum ceramic) is fixed with an aluminum jig and the Z300-VC10V3 controller is connected.
*9. For IP 67 items, please inquire.
C-36
Item
Measurement center
distance
Measurement range
Light source
Minimum beam shape *2
Linearity*3
Resolution*4
Sampling period *6
LED
indicator
Temperature drift*7
Environ-
mental
Resistant
Material
Cable length
Minimum bending radius
Weight
the work, detection errors may result.
pending on the object.
performance may not be satisfactory.
· Z300-S5
For more Information: U.S. www.sensors.omron.com
Measurement Modes
NEAR lamp
FAR lamp
Protective structure
Ambient illuminance
Ambient temperature
Ambient humidity
Vibration resistance
55mm
45mm
45mm
Model
100 mm
±20 mm
Visible semiconductor laser (wavelength 670 nm, 1 mW max., Class 2)
60 µm × 1000 µm typical (standard distance)
±0.1% F.S.
1 µm*5
500 µs (at high speed)
Illuminates when the object is near the measurement center distance, and is on the near side of the measurement center distance in the measurement
range. The lamp flashes when the object is out of the measurement range or insufficient light is received.
Illuminates when the object is near the measurement center distance, and is on the far side of the measurement center distance in the measurement
range. The lamp flashes when the object is out of the measurement range or insufficient light is received.
0.01% F.S. /°C
IEC 60529 IP67
Incandescent lamp: 3,000 lux max.
Operating: 0°C to 50°C, Storage: -15°C to 60°C (with no icing or condensation)
Operating/Storage: 35% to 85% RH (with no condensation)
10 to 150 Hz, 0.35-mm double amplitude for 8 minutes each in X, Y, and Z directions
Diecast aluminum
2 m
68 mm
Approx. 600 g
Diffuse reflection mode
±0.1%max.
55mm
Z300-S10 (long-range type)
Distance
94 mm
±16 mm
• Z300-S10
Regular reflection mode
120mm
80mm
Canada www.sensors.omron.ca
80mm
600 mm
±350 mm (F.S. 700 mm)
Visible semiconductor laser
(wavelength 658 nm, 15 mW max., Class 3B)
*1
0.3 mm × 16(10.3*) mm
(at 500 mm)
*Effective area of CCD
±0.07%F.S
(250 mm to 750 mm) ±0.1%F.S
(750 mm to 950 mm)
8 µm (at 250 mm)
40 µm (at 600 mm)
IEC Standard IP66*8
50 cm + extension cable
Approx. 1000 g
Diffuse reflection mode only
– 0.1%max.
(Super long-range type)
Z300-S60
120mm
Distance

Related parts for F150-M05L