F150-M05L Omron, F150-M05L Datasheet - Page 9

no-image

F150-M05L

Manufacturer Part Number
F150-M05L
Description
5.5Panel Mnt. Clr LCD Monitor
Manufacturer
Omron
Datasheets

Specifications of F150-M05L

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Controller: Z300-VC10V3/Z300-VC15V
* Measured at an average count of 64 times with our K3AS Linear Sensor Controller connected
C-38
Item mode
speci
speci
Weight
Accessories
Gen-
ance
tions
tions
fica-
Per-
form
fica-
eral
Power supply volt-
age
Current consump-
tion
Insulation resistance
Dielectric strength
Leakage current
Noise resistance
Vibration resistance 10 to 150 Hz (vibration width 0.1 mm) X, Y, Z directions 8 min.
Shock resistance
Ambient temperature Operating: 0 to +50°C, storage: -15 to +60°C (with no icing or condensation)
Ambient humidity
Ambient Conditions
Ground
Protective structure
Material
Number of
connected sensors
Number of scenes
Image recording
function
Processing method
Image pre-processing Noise elimination, smoothing
Average/filter
Light intensity follow
function
Applications
Range specification
2-area measure-
ment mode
Hold function
2-sensor measure-
ment mode
Measurement data
Calculation func-
tions
Result output
Terminal block
Monitor I/F
Analog output
resolution
For more Information: U.S. www.sensors.omron.com
21.6 to 26.4 V DC (including ripple)
1 A or less (when two sensors are connected)
Between external DC terminals and ground terminal: 20 MΩ or higher (using 100-V DC insulation resistance tester)
(with built-in surge protector disconnected)
Between external DC terminals and ground terminal: 1000 V AC 50/60 Hz (with built-in surge protector
disconnected)
10 mA max.
1500 V p-p, pulse width of 0.1 µs/1 µs, Rise: 1-ns pulse
200 m/s
Operating/storage: 35 to 85% RH (with no condensation)
No corrosive gas
D-type ground (ground resistance 100 Ω or less) * The previous No. 3 type grounding
Built-in panel type (IEC60529 Standard IP20)
Unit: ABS
2 units
16
Maximum of 20 rejection images, maximum of 4 peripheral images
Up to 4 work surface images can be recorded
Dark/light center, edge center
Average count (12 levels, 1 to 4096 times), HPF (high-pass filter)
Auto (light intensity follow range can be specified), fixed
(selected from 32 levels)
Select from following 8 types: surface displacement, spot
displacement, maximum height, groove/depression, lev-
el difference, thickness of transparent object, level differ-
ence (2 sensors), thickness (2 sensors)
Area of line beam direction + displacement direction can
be specified.
Absolute coordinate mode, relative coordinate mode
Sampling, peak, bottom, peak-to-peak, average, length
Simultaneous measurement, alternating measurement
4 outputs/scene
The following calculations are possible for each of OUT
0 to 3
K+A, K-A, K+(A+B), K+iA-B), K-(A+B)
A, B: Specified measurement points
K: Any constant
11 input points: TRIGGER, HOLD-RESET, LD-OFF,
21 output points: DO0 to DO20
1 CH (supports pin jack and over scan monitor)
Full-scale output at maximum of 40,000 levels Resolution * 0.25 mV (± V), 0.4 µA (4-20 µA)
Approximately 700 g (unit only)
Operation manual, 1 resistor (250 Ω, 1/2 W)
Decision output (HIGH, PASS, LOW, ERROR)
• Measured value output (measured value)
2
, 6 directions, 3 times each
RS-232C output
Terminal block output
RS-232C output
Terminal block output
Analog output
ALL-ZERO, ZERO0, ZERO1, RESET,
DI0 to DI3
VISUAL mode
Canada www.sensors.omron.ca
1 unit
1
Edge center
None
Average count (SLOW: 64 times, FAST: 1 time)
Auto (light intensity follow range cannot be spec-
ified), fixed (selected from HIGH or LOW)
1
Analog output of measured values
LD-OFF
NON VISUAL mode

Related parts for F150-M05L