H3DE-F AC/DC24-230 Omron, H3DE-F AC/DC24-230 Datasheet - Page 3

TIMER DIN MNT 22.5mm

H3DE-F AC/DC24-230

Manufacturer Part Number
H3DE-F AC/DC24-230
Description
TIMER DIN MNT 22.5mm
Manufacturer
Omron
Series
H3DE-Fr
Datasheet

Specifications of H3DE-F AC/DC24-230

Relay Type
Integrated
Function
Interval
Circuit
SPDT (1 Form C)
Delay Time
0.1 Sec ~ 12 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24 ~ 230VAC/DC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3DE-FAC/DC24-230
H3DEFACDC24230
Specifications
■ General
Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.
■ Time Ranges
Note: When the main dial is set to “0” for all settings, the output will operate instantaneously.
■ Ratings
Note: 1. DC ripple rate: 20% max.
Operating mode
Terminal block
Terminal screw tightening
torque
Input type
Output type
Mounting method
Attachment
Approved standards
x 0.1
x 1
Rated supply voltage
(see notes 1 and 2)
Operating voltage range
Power reset
Reset voltage
Power consump-
tion (see note 3)
Voltage input
Control output
Ambient temperature
Ambient humidity
Time scale display
2. Since an inrush current of 0.25 A will occur when using the power supply voltage at 24 VDC, pay careful attention when turning on or off
3. The power consumption is for mode A after the Timer counts the time-up time and for the AC input at 50 Hz. The power consumption of
the power supply to the Timer with a solid-state output such as a sensor.
the H3DE-M@ includes the input circuit with the B1 and A1 terminals short-circuited.
Item
H3DE-M1
H3DE-M2
H3DE-S1
H3DE-S2
0.1 to 1.2 s
1 to 12 s
A: ON-delay (Signal or Power)
B: Flicker OFF start (Signal or Power)
B2: Flicker ON start (Signal or Power)
C: Signal ON/OFF-delay
D: Signal OFF-delay
E: Interval (Signal or Power)
G: Signal ON/OFF-delay
J: One-shot (Signal or Power)
Clamps two 2.5 mm
0.98 N·m max. {approx. 10 kgf·cm max.}
Voltage input
Relay: DPDT
DIN track mounting (see note)
Nameplate
UL508, CSA 22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)
sec
H3DE-M2
24 to 230 VAC/DC (50/60 Hz)
12 VDC (H3DE-M2 model only)
85% to 110% of rated supply voltage
Minimum power-off time: 0.1 s
2.4 VAC/DC max.
AC: approx. 4.3 VA (2.2 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
AC: approx. 4.8 VA (2.4 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
AC: approx. 2.7 VA (1.6 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
AC: approx. 3.2 VA (1.9 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
Max. permissible capacitance between input lines (terminals B1 and A2): 2000 pF
Load connectable in parallel with inputs (terminals B1 and A2)
H-level: 20.4 to 253 VAC/DC
L-level: 0 to 2.4 VAC/DC
Contact output: 5 A at 250 VAC with resistive load (cosφ = 1)
Operating: -10°C to 55°C (with no icing)
Storage:
Operating: 35% to 85%
2
max. bar terminals without sleeves.
-25°C to 65°C (with no icing)
0.1 to 1.2 min
1 to 12 min
5 A at 30 VDC with resistive load (cosφ = 1)
Relay: SPDT
min
H3DE-M1
Time unit display
0.1 to 1.2 h
1 to 12 h
A: ON-delay
B2: Flicker ON start
E: Interval
J: One-shot
---
Relay: DPDT
hrs
H3DE-S2
1 to 12 h
10 to 120 h
Relay: SPDT
H3DE-M/-S
H3DE-S1
10 h
3

Related parts for H3DE-F AC/DC24-230