XS2R-D526-S003 Omron, XS2R-D526-S003 Datasheet - Page 8

no-image

XS2R-D526-S003

Manufacturer Part Number
XS2R-D526-S003
Description
F3W-D Y PLUG
Manufacturer
Omron
Datasheets

Specifications of XS2R-D526-S003

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Nomenclature
NPN Open Collector Output Models
Emitter
F3W-D052A(P)-L
F3W-D052B(P)-L
Safety Precautions
Refer to Warranty and Limitations of Liability.
Do not apply the F3W-D as safety mechanisms used
in pressing machines or any other safety
mechanisms for protecting the human body from
danger.
(1) Do not apply the F3W-D as safety mechanisms used in pressing
(2) The F3W-D is designed for detection of the human body or moving
(3) The F3W-D or any product incorporating the F3W-D may be
Before using more than one F3W-D Sensor in parallel or series, take
necessary countermeasures against mutual interference so that the
Sensors will not malfunction. Refer to
Function
● Operating Environment
• Do not use the Sensor in an environment containing flammable or
• Do not use the Sensor underwater.
• Do not disassemble, repair, or modify the Sensor.
• Always turn OFF the system power before installing or replacing the
volatile gases.
Sensor.
machines, shears, rolling machines, spinning machines, cotton
mill machines, or robots for the protection of an operator’s hands
and body.
objects in the detection area but not for protection against danger.
exported to any country. Should the F3W-D cause any problem
conflicting with local laws or related to product liability locally,
however, OMRON shall, without exception, assume no
responsibility for it.
Power
indicator
(green)
on the right.
Operation
cover
Different
frequency
indicator (green)
Precautions for Safe Use
http://www.ia.omron.com/
WARNING
CAUTION
Detection
side
DIP switch 1
mode setting
switch
Picking
indicators
(orange)
Mutual Interference Prevention
Receiver
F3W-D052A(P)-D
F3W-D052B(P)-D
Operation
cover
Stability
indicator
(green)
Operation
indicator
(orange)
8
UNI-WIRE Direct Connection Models
Do not use the product in atmospheres or environments that exceed
product ratings.
● System Design
Mutual Interference Prevention Function
(1) Two Sets of Sensors:
Set these Sensors to different frequencies with the frequency
selector. Refer to DIP Switch 1 Mode Switching on page 7.
If the mutual interference prevention function is not used, and there
are two Sensors with the same frequency setting, a beam from the
Emitter of one Sensor may hit the Receiver of the other Sensor,
resulting in malfunction.
This function cannot prevent mutual interference between the F3W-D
Sensor and a Photoelectric Sensor of a different model.
(2) Three or More Sets of Sensors:
When 3 or more sets of Sensors are used in parallel, mutual
interference may result in malfunction. Take the following measures
to prevent mutual interference, and check for mutual interference.
While in LONG mode, the Sensors are more easily affected by
interference. Therefore, if the distance between the Emitter and
Receiver of a Sensor is 1 m or less, use the SHORT mode.
Emitter
F3W-D052U(P)-L
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
Power
indicator
(green)
Operation
cover
Different
frequency
indicator
(green)
Precautions for Correct Use
Transmission
indicator (orange)
Picking
indicators
(orange)
Detection
side
DIP switch 1
mode setting
switch
DIP switch 2
instruction
input address
setting switch
DIP switch 3
Control output
address setting
switch
Receiver
F3W-D052U(P)-D
Transmission
indicator (orange)
Operation cover
Stability
indicator
(green)
Operation
indicator
(orange)
F3W-D
8

Related parts for XS2R-D526-S003