AT-GM-11KM BANNER ENGINEERING, AT-GM-11KM Datasheet - Page 11

no-image

AT-GM-11KM

Manufacturer Part Number
AT-GM-11KM
Description
AT-GM-11KM TWO-HAND CTL W/MUTI
Manufacturer
BANNER ENGINEERING
Datasheet
DUO-TOUCH
checkout procedure, make certain all power
is disconnected from the machine to be
controlled. Temporarily disconnect the wires
connected to the outputs of the DUO-TOUCH
SG Safety Module at terminals 13/14, 23/24,
31/32, Y32, and Y33.
checks cannot be verified, the two-hand-
control system must not be used until the
problem has been corrected. Injury or
death to personnel may result from
attempts to use the machine under such
conditions.
!
!
Banner Engineering Corp.
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
www.bannerengineering.com • Tel: 763.544.3164
CAUTION ...
Power Before Checkout
Before performing the initial
WARNING ...
Use System Until
Checkouts Are Verified
If all of the described
®
SG –
Disconnect
Do Not
Minneapolis MN, U.S.A.
Minneapolis, MN U.S.A.
Models AT-GM-11KM and AT-HM-11KM Two-Hand Control Modules
To perform the initial checkout, it is necessary to view the red Fault LED and the six green
Status indicators. Proceed with caution around open wiring.
If the SSI inputs are to be used, verify the checkout procedures for the external safety
systems or other devices connected to the SSI inputs as described by the appropriate
manuals. Do not proceed until all checkout procedures are completed successfully and
all problems have been corrected.
1) Verify that the two actuating devices are properly connected.
2) Apply power to the Safety Module and to the actuating devices, if applicable.
3) Verify that the Power indicator is ON. The SSI indicator may be ON if the Safety Stop
4) With the SSI input closed (i.e., SSI LED is ON), activate both hand controls
5) Again, activate the two hand controls simultaneously, and hold them engaged.
6) Activate only one hand control and hold it engaged. Input 1 (or Input 2) indicator
7) Release both hand controls, and open the SSI inputs (if used). Verify that the SSI
8) Remove power from the Safety Module and disconnect the monitor contact feed-
If the DUO-TOUCH SG Safety Module passes all of these tests, reconnect power to the
machine and the output wires at terminals 13/14, 23/24, 31/32, Y31, and Y32. Also
reconnect the monitor contact feedback loop at terminals Y1 and Y2. Do not attempt to
use the DUO-TOUCH SG Two-Hand Control Safety Module until all of the previous
tests are passed.
9) At this time, perform the Daily Checkout to verify muting function and proper
Interface is jumpered (i.e., not used) or if the connected device is in a closed/GO
condition. If any other Safety Module indicators are ON, disconnect the power to the
Safety Module and check all wiring. Do not continue this checkout procedure until
the cause of the problem is corrected.
simultaneously (within 0.5 seconds), and hold them engaged. The Output
indicators should come ON. Release both hand controls simultaneously. The
Output indicators should go OFF.
The Output indicators should come ON. Release one hand control while holding the
other engaged. One of the Input indicators should remain ON. Re-activate the hand
control that was just released. The Input indicator that was OFF should remain OFF.
Release both hand controls. Input 1 and Input 2 indicators should then be OFF.
should come ON. After more than
Input 1 (Input 2) indicator should remain ON, while Input 2 (Input 1) indicator
remains OFF.
LED turns OFF. Activate both hand controls simultaneously (within 0.5 seconds),
and hold them engaged. Input 1 and Input 2 indicators should come ON, but the
Output LED must remain OFF.
back loop at terminals Y1 and/or Y2. Re-apply power to the Safety Module. Close
the SSI inputs, and activate both hand controls simultaneously. Input 1 and Input 2
indicator LEDs should remain OFF.
operation.
Initial Checkout Procedure
1
/
2
second, activate the second hand control.
P/N 109782
11

Related parts for AT-GM-11KM