IDP06E60 Infineon Technologies, IDP06E60 Datasheet

no-image

IDP06E60

Manufacturer Part Number
IDP06E60
Description
DIODE 600V 14.7A TO220-2
Manufacturer
Infineon Technologies
Datasheet

Specifications of IDP06E60

Package / Case
TO-220-2
Voltage - Forward (vf) (max) @ If
2V @ 6A
Voltage - Dc Reverse (vr) (max)
600V
Current - Average Rectified (io)
14.7A (DC)
Current - Reverse Leakage @ Vr
50µA @ 600V
Diode Type
Standard
Speed
Fast Recovery =< 500ns, > 200mA (Io)
Reverse Recovery Time (trr)
70ns
Mounting Type
Through Hole
Product
Switching Diodes
Peak Reverse Voltage
600 V
Forward Continuous Current
14.7 A
Max Surge Current
29 A
Configuration
Single
Recovery Time
70 ns
Forward Voltage Drop
2 V
Maximum Reverse Leakage Current
50 uA
Operating Temperature Range
- 55 C to + 175 C
Maximum Operating Temperature
+ 175 C
Minimum Operating Temperature
- 55 C
Mounting Style
Through Hole
Packages
PG-TO220-2
If (typ)
6.0 A
If (max)
14.7 A
If,sm (max)
29.0 A
Vf (typ)
1.5 V
Ir (max)
50.0 µA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Capacitance @ Vr, F
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDP06E60
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Fast Switching EmCon Diode
Type
IDP06E60
Maximum Ratings, at T
Parameter
Repetitive peak reverse voltage
Continous forward current
T
T
Surge non repetitive forward current
T
Maximum repetitive forward current
T
Power dissipation
T
T
Operating and storage temperature
Soldering temperature
wavesoldering, 1.6mm (0.063 in.) from case for 10s
Rev.2.2
Feature
• 600 V EmCon technology
• Fast recovery
• Soft switching
• Low reverse recovery charge
• Low forward voltage
• 175°C operating temperature
• Easy paralleling
C
C
C
C
C
C
=25°C
=90°C
=25°C, t
=25°C, t
=25°C
=90°C
p
p
=10 ms, sine halfwave
limited by T
Package
PG-TO220-2-2.
jmax
, D=0.5
j
= 25 °C, unless otherwise specified
Ordering Code
Page 1
-
Symbol
V
I
I
I
P
T
T
F
FSM
FRM
j ,
S
RRM
tot
T
stg
Marking
D06E60
Product Summary
V
I
V
T
F
RRM
F
jmax
-55...+175
Pin 1
Value
C
14.7
46.9
26.6
600
260
10
29
22
C
PG-TO220-2-2.
PIN 2
A
2007-04-24
IDP06E60
600
175
A
1.5
6
PIN 3
Unit
V
A
W
°C
°C
-
°C
C
V
A
V

Related parts for IDP06E60

IDP06E60 Summary of contents

Page 1

... Rev.2.2 Ordering Code - = 25 °C, unless otherwise specified Symbol FSM I FRM Page 1 Product Summary V RRM jmax PG-TO220-2-2. C Marking Pin 1 PIN 2 C D06E60 Value 600 RRM 14 tot 46.9 26.6 -55...+175 T stg 260 IDP06E60 600 1.5 V 175 ° PIN Unit °C °C 2007-04-24 ...

Page 2

... Device on 40mm*40mm*1.5mm epoxy PCB FR4 with 6cm² (one layer, 70 µm thick) copper area for drain connection. PCB is vertical without blown air. Rev.2.2 Symbol R thJC R thJA R thJA = 25 °C, unless otherwise specified j Symbol Page 2 IDP06E60 Values Unit min. typ. max 3.2 K ...

Page 3

... Symbol t rr =25°C j =125°C j =150° rrm =25°C j =125°C j =150° =25°C j =125°C j =150° =25°C j =125°C j =150°C j Page 3 IDP06E60 Values Unit min. typ. max 100 - - 105 - 240 - - 360 - - 400 ...

Page 4

... Rev.2.2 2 Diode forward current I = f(T F parameter 125 °C 175 Typ. diode forward voltage 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1 Page ≤ 175° 100 125 ) j 2 12A -60 - IDP06E60 °C 175 T C 100 °C 160 T j 2007-04-24 ...

Page 5

... Typ. reverse recovery softness factor S = f(di = 125°C parameter: V 600 A/µs 800 di /dt F Page 5 /dt 400V 125 ° 12A 6A 3A 200 300 400 500 600 /dt 400V 125° 200 300 400 500 600 700 IDP06E60 A/µs 800 di /dt F 12A 6A 3A 800 A/µs 1000 di /dt F 2007-04-24 ...

Page 6

... Max. transient thermal impedance thJC p parameter : IDP06E60 10 K single pulse - Rev.2 0.50 0.20 0.10 0.05 0.02 0. Page 6 IDP06E60 2007-04-24 ...

Page 7

... Rev.2 symbol Page 7 IDP06E60 PG-TO-220-2-2 dimensions [mm] [inch] min max min max A 9.70 10.10 0.3819 0.3976 B 15.30 15.90 0.6024 0.6260 C 0.65 0.85 0.0256 0.0335 D 3.55 3.85 0.1398 0.1516 E 2.60 3.00 0.1024 0.1181 F 9.00 9.40 0.3543 0.3701 G 13.00 14.00 0.5118 0.5512 H 17.20 17.80 ...

Page 8

... Life support devices or systems are intended to be implanted in the human body support and/or maintain and sustain and/or protect human life. If they fail reasonable to assume that the health of the user or other persons may be endangered. Rev.2.2 Page 8 IDP06E60 2007-04-24 ...

Related keywords