FX-305 PANASONIC EW, FX-305 Datasheet - Page 101

no-image

FX-305

Manufacturer Part Number
FX-305
Description
[NAVI] DIGITAL, RED, NPN, 12-24VDC, QD, 2OUTPUT
Manufacturer
PANASONIC EW
Datasheet
Two zones can be monitored with the SD3-A1: the warning
zone within a radius of 15m, and the protection zone within a
radius of 4m. You can configure the contours of these zones
to perfectly accomodate any application. You can configure up
to eight zone patterns and switch between them at any given
time, even during operation. This flexible zone configuration
can be done by PC.
By activating the reference boundary function which enables
constant detection of stationary objects, the safety laser scan-
ner memorizes the position of stationary objects, and monitors
for beam misalignment after installation.
Compatible OS: Windows XP/2000/
Note: Windows is a registered trademark
or trademark of Microsoft Corp. in
the U.S. and/or other countries.
NT/98/95
RS-232C
RS-422
Warning zone
Detection zone
The safety laser scanner
memorizes the position
o f s t a t i o n a r y o b j e c t s
and monitors for beam
m i s a l i g n m e n t i n t h e
detection zone.
04/2011
The response time can be adjusted from 80 to 640ms. Mutual
interference can be prevented by adjusting the response time
when setting up multiple safety laser scanners in close vicinity.
Configurations can be saved in the optional configuration plug’s
built-in memory and reloaded after maintenance or exchanging
safety laser scanners.
Configuration
plug
101

Related parts for FX-305