FX-305 PANASONIC EW, FX-305 Datasheet - Page 102

no-image

FX-305

Manufacturer Part Number
FX-305
Description
[NAVI] DIGITAL, RED, NPN, 12-24VDC, QD, 2OUTPUT
Manufacturer
PANASONIC EW
Datasheet
Warning and machine halt zones are
implemented to detect workers in dan-
gerous areas.
Prevent injuries from a moving AGV.
Monitor fallen cargo to avoid collisions.
102
SD3-PS (exclusive 15-pin connector): 1 pc., SD3-RS232 (exclusive 9-pin connector): 1 pc., Mounting screws [M5 (length 20 mm) hexagon-socket-head bolt: 2 pcs.,
Sensing range (radius)
Min. sensing object
setting
The scanner is used to slow down the
vehicle upon detection in the warning
zone and stop the vehicle upon enter-
ing the protection zone.
One safety laser scanner can safeguard
the front opening where in the past two
sets of light curtains were needed.
1 set, Simplified instruction manual: 1 copy, Installation CD-ROM (includes detailed instruction manual data): 1 CD
M5 (length 16mm) hexagon-socket-head bolt: 2 pcs., attached to SD3-PS]:
Main body: Die-cast aluminium, Scanner window: Thermoplastic resin
Net weight: 2.1kg approx., Gross weight: 2.9kg approx.
300mA approx. (excluding external connection load)
Rated operating voltage: supply voltage (UB) -3.2V
Max. measurement range (radius) 50m (fixed)
PNP open-collector transistor 2 outputs
04/2011
Max. 7 + 1 (without detection zone)
0 to +50°C, Storage: -20 to + 60°C
Residual voltage: 3.2V or less
Max. source current: 250mA
Install two safety laser scanners to
build a protection zone surrounding
the object in question. Deactivating
the zone is also possible.
190° / 180° (by setting)
The scanner detects a human body
whenever it enters the field.
Class 1 (IEC 60825)
24V DC+20 -30%
200mm
IP65
ø150mm (fixed)
0 to 15m