E5-648-C2422 EATON CUTLER HAMMER, E5-648-C2422 Datasheet - Page 13

no-image

E5-648-C2422

Manufacturer Part Number
E5-648-C2422
Description
PRESET COUNTER, 6-DIGIT, 10VDC TO 30VDC
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of E5-648-C2422

No. Of Digits / Alpha
6
Digit Height
9mm
Supply Voltage Range
10VDC To 30VDC
Power Consumption
90W
Counting Speed
50kHz
Operating Temperature Range
-20°C To +65°C
E5-648-C242x
electronic preset counter
with two presets
7.9 Setting the presets
7.9.1 Setting via decade keys
In programming mode preset 2 will always be displayed in the
lower line. This is except for the output operations AddBat,
SubBat, AddTot and SubTot.
7.9.2 Setting with Teach-In function
Briefly activate the MPI (NPN or PNP input logic)
7.9.3 Setting the tracking presets (trail)
If a tracking preset has been programmed, the value for
preset 2 can be set either via the decade keypad or via the
Teach-In function.
However the value for preset 1 must be entered via the
decade keypad. In this instance, it is not possible to use the
Teach-In function.
The current count value will be adopted as the
new preset value
The preset value can subsequently be further modified
via the decade keypad
Press the Prog/Mode key until the preset
to be changed is displayed—
Press any decade key
Display switches to the editor mode
Set the desired preset value using the
decade keys
Press the Prog/Mode key to confirm the
value and save it
Display switches to the editor mode of the
next preset
Approx. 3s after the last press of the
decade keys, or by pressing the Reset key,
the new preset value will be accepted
and the counter will switch back to
operating mode
Program the MPI input to tEAch
In programming mode, select the preset
to be changed using the Prog/Mode key
or
or
7.10 Set function
Both the pulse counter and the timer can be set to a default value
by means of the Set function.
Briefly activate the MPI (NPN or PNP input logic)
8. error message
Message
Err 1
In Adding modes: the pulse counter or timer will be set to the
SEtPt value
In Subtracting modes: the pulse counter or timer will be set to
a value that is the sum of Preset 2 value and the value of SEtPt
eaton corporation www.eaton.com
Description
Set value is outside the permitted range
Program the MPI input to SEt
Set menu item SEtPt to the desired value
Instruction leaflet IL05407002E
Effective October 2010
13