E5-648-C2422 EATON CUTLER HAMMER, E5-648-C2422 Datasheet - Page 9

no-image

E5-648-C2422

Manufacturer Part Number
E5-648-C2422
Description
PRESET COUNTER, 6-DIGIT, 10VDC TO 30VDC
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of E5-648-C2422

No. Of Digits / Alpha
6
Digit Height
9mm
Supply Voltage Range
10VDC To 30VDC
Power Consumption
90W
Counting Speed
50kHz
Operating Temperature Range
-20°C To +65°C
E5-648-C242x
electronic preset counter
with two presets
Lock input
7.8.5.2 Main menu for configuration
Multiplication factor
Division factor
Display mode
Decimal point setting
Moving average
Calculation and display of the
frequency/speed in 1/s
Calculation and display of the
frequency/speed in 1/min
When the Lock input is activated,
the programming is inhibited
When the Lock input is activated the
setting of the preset values is inhibited
When the Lock input is activated
the setting of the preset values and
the programming are both inhibited
Main menu for matching the
input pulses and display
Multiplication factor can be programmed
from 00.0001 to 99.9999.
The setting 00.0000 will not be accepted
Division factor can be programmed from
01.0000 to 99.9999.
The setting <01.0000 will not be accepted
Decimal point (determines the resolution)
0
0.0
0.00
0.000 3 decimal places
Moving average calculated
AVG 2:
AVG 5:
AVG 10: over 10 measurements
AVG 20: over 20 measurements
no decimal place
1 decimal place
2 decimal places
over 2 measurements
over 5 measurements
Start delay
Waiting time
7.8.5.3 Preset 1
See below 7 .8.6.5
7.8.5.4 Preset 2
See below 7 .8.6.6
7.8.6 Timer
7.8.6.1 Main menu for Signal and Control inputs
Input polarity
Filter for the signal inputs Inp A and Inp B
eaton corporation www.eaton.com
Programmable from 00.0 to 99.9s
At the start of a measurement the
measurement results within this
time-period are ignored
Programmable from 00.1 to 99.9s.
This value specifies how much time
should elapse, after the last valid edge,
before zero is to be displayed
Main menu for programming the signal and
control inputs
PNP: switching to Plus
for all inputs in common
nPn: switching to 0V
for all inputs in common
For electronic control of the signal inputs
For mechanical control of the signal inputs
(for control with mechanical contacts)
Instruction leaflet IL05407002E