89750150 Crouzet USA, 89750150 Datasheet - Page 137

Programmable Logic Controller

89750150

Manufacturer Part Number
89750150
Description
Programmable Logic Controller
Manufacturer
Crouzet USA
Datasheets

Specifications of 89750150

Supply Voltage
24VDC
Operating Temperature Range
-10°C To +60°C
Height
85 mm
Length
85 mm
Primary Type
Temperature
Standards
IP30 Protection Casing
Temperature, Ambient
-10 to +60 °C
Temperature, Operating
-10 to +40 °C
Thickness
80 mm
Voltage, Rating
24 VDC ± 10%
For Use With
Millennium Series PLCs
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
For more information www.crouzet.com
Dimensions
EIL / EIH / EIT
Connections
EIL / EIH
Principles
AC/DC control with memory
AC/DC control without memory
Un
1
2
3
2
1
4
1
2
3
2
1
4
Un
B
C
D
E
F
G
H
3,5
(+)
(-)
Threshold
Hysteresis
UPPER function
UNDER function
Unit power-up
Controlled current
Memory
T2
T2
T2
T2
A2
A1
32
U
T1
T1
T1
T1
E1
(+)
95
(+)
I
E2
(-)
M
63
E3
(+)
T1
T1
T2
T2
12
5
R
11
T1
T1
T2
T2
A1 15 Y1
18 16 A2
14
22,5
5
6
2
2
6
5
6
2
6
2
EIT
A1 - A2 : Supply voltage
Operating principle
AC/DC control without memory
When the value of the controlled current, either AC or DC, reaches the threshold displayed on the
front face, the output relay changes state at the end of time delay T1.
It returns instantly to the initial state when the current drops below the hysteresis threshold, or when
the power supply is disconnected.
AC/DC control with memory
The output relay changes state at the end of time delay T1 and remains latched in this position. To
reset the memory function the auxiliary supply must be disconnected.
Over-current function (UPPER)
The time delay on energisation T2 prevents current peaks due to motor starting.
The delay on upward crossing of threshold T1 provides immunity to transients and other
interference, thereby preventing spurious triggering of the output relay.
Under-current function (UNDER)
The time delay on energisation T2 prevents the occurrence of current troughs. The delay on
downward crossing of threshold T1 provides immunity to random dips, thereby preventing spurious
triggering of the output relay.
Note : In underload function, the absolute value of the hysteresis cannot be greater than the
measurement range maximum.
B
C
D
E
F
G
Threshold
Hysteresis
UPPER function
UNDER function
Unit power-up
Controlled current
A2
A1
U
(+)
E1
I
(-)
M
12
R
11
14
137