89750150 Crouzet USA, 89750150 Datasheet - Page 74

Programmable Logic Controller

89750150

Manufacturer Part Number
89750150
Description
Programmable Logic Controller
Manufacturer
Crouzet USA
Datasheets

Specifications of 89750150

Supply Voltage
24VDC
Operating Temperature Range
-10°C To +60°C
Height
85 mm
Length
85 mm
Primary Type
Temperature
Standards
IP30 Protection Casing
Temperature, Ambient
-10 to +60 °C
Temperature, Operating
-10 to +40 °C
Thickness
80 mm
Voltage, Rating
24 VDC ± 10%
For Use With
Millennium Series PLCs
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
3
74
To order, see page 6
Analogue TMR 48
Type
TMR 48 U
TMR 48 A
TMR 48 X
TMR 48 L
Specifications
Accessories
11-pin connector base
8-pin connector base
Spring clips (packet of 2)
Black front face. For grey and other colours
General characteristics
Supply voltage Un
Operating range
Frequency
Power consumption
Timing ranges (14 available options)
Repetition accuracy
Temperature drift according to CEI/EN 61812
Display accuracy
Minimum pulse duration START
Minimum pulse duration GATE
Minimum pulse duration RESET
Start-up delay after power cut (START linked)
Output specification
Nominal rating
Nominal insulation voltage
Rated power (resistive load)
Minimum current
Electrical life at I max. 250 V AC resistive (number of operations)
Mechanical life (operations)
Function and use
Display of output state by 2 LEDs
Operating temperature range (°C)
Storage temperature range (°C)
Breakdown voltage
Protection class (IEC 60529) - Panel-mounted
Protection class (IEC 60529) - Casing
Material housing
Weight (g)
Multi-function or mono-function
Multi-range from 0.02 s to 300 h
Multi-voltage 12 to 240 VDC / 24 to 240 V AC
Time setting displayed on dial
2 changeover relays 5 A / 250 VAC
Display of power and output states by 2 LEDs
Housing 48 x 48 mm
TMR 48
Functions
A, B, C, W, G, Ac, Bw
A
A1, A2, H1, H2, Q1, Q2, D-Di
L, Li, G, Gi
Relay outputs
2 timed changeover
2 timed changeover
2 changeover or 1 timed
and 1 instantaneous
2 timed changeover
Max. breaking current
5 A / 250 VAC
5 A / 250 VAC
5 A / 250 VAC
5 A / 250 VAC
12
24
± 10 % DC supply
- 15 % / + 10 % AC supply
50 / 60 Hz
4.8 VA / 230 VAC
2.5 VA / 110 VAC
1.1 VA / 24 VAC
0.5 W / 24 VDC
0.8 W / 12 VDC
0,02
0,05
0,2
0,5
2
5
± 0.5 % of full scale at 25°C (typical with constant parameters)
± 0.05 % of full scale
± 5 % of full scale at 25°C
25 ms
60 ms
60 ms
50 ms
2 x 5 A
250 VAC
2000 VA
10 mA
10
30 x 10
Green : power ON, flashing during timing
Yellow : ON output ON, OFF output OFF
-20
-40
2 KV
IP 50
IP 40
self-extinguishing
140
5
120 s
300 s
240 VDC
240 V AC
12 s
30 s
+55
+70
1,2 s
3 s
6
0,2
0,5
2
5
120 min.
300 min.
12 min.
30 min.
Supply voltage
12
24
12
24
12
24
12
24
240 VDC
240 VAC
240 VDC
240 VAC
240 VDC
240 VAC
240 VDC
240 VAC
0,2
0,5
2
5
120 h
300 h
12 h
30 h
Connection
Plug-in 11 way
Plug-in 8 way
Plug-in 8 way
Plug-in 11 way
For more information www.crouzet.com
Code
88 886 016
88 886 106
88 886 116
88 886 516
25 622 080
25 622 130
79 237 740
please consult us
Code

Related parts for 89750150