CS42426-CQZR Cirrus Logic Inc, CS42426-CQZR Datasheet - Page 51

Audio CODECs IC 192kHz 110dB 6Ch Multi-Ch CODEC

CS42426-CQZR

Manufacturer Part Number
CS42426-CQZR
Description
Audio CODECs IC 192kHz 110dB 6Ch Multi-Ch CODEC
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS42426-CQZR

Number Of Adc Inputs
2
Number Of Dac Outputs
6
Conversion Rate
192 KSPs
Interface Type
Serial (I2C, SPI)
Resolution
24 bit
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Package / Case
LQFP-64
Minimum Operating Temperature
- 10 C
Number Of Channels
2 ADC, 6 DAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS42426-CQZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS42426-CQZR
Manufacturer:
CIRRUS
Quantity:
20 000
DS604F1
6.10
6.10.1 SINGLE VOLUME CONTROL (SNGVOL)
6.10.2 SOFT RAMP AND ZERO CROSS CONTROL (SZCX)
Reserved
7
Volume Transition Control (address 0Dh)
Immediate Change
Zero Cross
Soft Ramp
Soft Ramp on Zero Crossing
Default = 0
Function:
Default = 00
00 - Immediate Change
01 - Zero Cross
10 - Soft Ramp
11 - Soft Ramp on Zero Crossings
Function:
The individual channel volume levels are independently controlled by their respective Volume Control
registers when this function is disabled. When enabled, the volume on all channels is determined by
the A1 Channel Volume Control register and the other Volume Control registers are ignored.
When Immediate Change is selected, all level changes will take effect immediately in one step.
Zero Cross Enable dictates that signal-level changes, either by attenuation changes or muting, will
occur on a signal zero crossing to minimize audible artifacts. The requested level-change will occur
after a timeout period between 512 and 1024 sample periods (10.7 ms to 21.3 ms at 48 kHz sample
rate) if the signal does not encounter a zero crossing. The zero cross function is independently mon-
itored and implemented for each channel.
Soft Ramp allows level changes, both muting and attenuation, to be implemented by incrementally
ramping, in 1/8 dB steps, from the current level to the new level at a rate of 1 dB per 8 left/right clock
periods.
Soft Ramp and Zero Cross Enable dictates that signal level changes, either by attenuation changes
or muting, will occur in 1/8 dB steps and be implemented on a signal zero crossing. The 1/8 dB level
change will occur after a timeout period between 512 and 1024 sample periods (10.7 ms to 21.3 ms
at 48 kHz sample rate) if the signal does not encounter a zero crossing. The zero cross function is
independently monitored and implemented for each channel.
SNGVOL
6
SZC1
5
SZC0
4
AMUTE
3
ADC_SP
MUTE
2
RAMP_UP
1
CS42426
RAMP_DN
0
51

Related parts for CS42426-CQZR