CS44600-CQZR Cirrus Logic Inc, CS44600-CQZR Datasheet - Page 50

Audio Amplifiers 6ch 24-bit 192kHz Dig. Amp Cntrlr T&R

CS44600-CQZR

Manufacturer Part Number
CS44600-CQZR
Description
Audio Amplifiers 6ch 24-bit 192kHz Dig. Amp Cntrlr T&R
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS44600-CQZR

Operating Supply Voltage
2.5 V
Supply Current
150 mA
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 10 C
Supply Type
Digital
Supply Voltage (max)
2.62 V
Supply Voltage (min)
2.37 V
Package / Case
LQFP-64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
50
7.3.5
7.3.6
7.4
7.4.1
RESERVED
7
PWM Channel Power Down Control (address 03h)
Power Down Output Mode (PDN_OUTPUT_MODE)
Default = 0
0 - PWM Outputs are driven low during power down
1 - PWM Outputs are driven to the inactive state during power down
Function:
This bit is used to select the power-down state of the PWM output signals. When set to 0, each channel
which has been powered down, following the ramp-down cycle if enabled, will drive the output signals,
PWMOUTxx+ and PWMOUTxx-, low.
When set to 1, each channel which has been powered down, following the ramp-down cycle if enabled,
will drive the output signals to the inactive state. PWMOUTxx+ is driven low and PWMOUTxx- is driven
high.
Power Down (PDN)
Default = 1
0 - Normal Operation
1 - Power down
Function:
The entire device will enter a low-power state when this function is enabled, and the contents of the control
registers are retained in this mode. The power-down bit defaults to ‘enabled’ on power-up and must be
disabled before normal operation can occur.
Power Down PWM Channels (PDN_PWMB3:PDN_PWMA1)
Default = 11111111
0 - Normal Operation
1 - Power down PWM channel
Function:
The specific PWM channel is in the power-down state. All processing is halted for the specific channel,
but does not alter the setup or delay register values. The PWM output signals are driven to the appropriate
logic level as defined by the Power-Down Output Mode bit, PDN_OUTPUT_MODE. When set to normal
operation, the specific channel will power up according to the state of the RAMP[1:0] bits and the channel
output configuration selected. When transitioning from normal operation to power down, the specific chan-
nel will power down according to the state of the RAMP[1:0] bits and the channel output configuration se-
lected. Ramp control is found in
RESERVED
6
PDN_PWMB3
5
“Ramp Configuration (address 05h)” on page
PDN_PWMA3
4
PDN_PWMB2
3
PDN_PWMA2
2
PDN_PWMB1
54.
1
CS44600
PDN_PWMA1
DS633F1
0

Related parts for CS44600-CQZR