DS3154 Maxim Integrated Products, DS3154 Datasheet - Page 36

no-image

DS3154

Manufacturer Part Number
DS3154
Description
Network Controller & Processor ICs Quad DS3-E3-STS-1 Li ne Interface Unit ST
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS3154

Product
Framer
Number Of Transceivers
4
Data Rate
51.840 Mbps
Supply Voltage (max)
3.465 V
Supply Voltage (min)
3.135 V
Supply Current (max)
400 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Package / Case
TE-CSBGA

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS3154
Manufacturer:
DS
Quantity:
65
Part Number:
DS3154
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS3154
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS3154+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS3154A2
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS3154A2
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS3154N
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS3154N#
Manufacturer:
Maxim Integrated
Quantity:
10 000
DS3151/DS3152/DS3153/DS3154 Single/Dual/Triple/Quad DS3/E3/STS-1 LIUs
12.4
JTAG Test Registers
IEEE 1149.1 requires a minimum of two test registers—the bypass register and the boundary scan register. An
optional test register, the identification register, has been included in the device design. It is used with the IDCODE
instruction and the Test-Logic-Reset state of the TAP controller.
Bypass Register. This single 1-bit shift register, used with the BYPASS, CLAMP, and HIGHZ instructions,
provides a short path between JTDI and JTDO.
Boundary Scan Register. This register contains a shift register path and a latched parallel output for control cells
and digital I/O cells. DS315x BSDL files are available at www.maxim-ic.com/TechSupport/telecom/bsdl.htm.
Identification Register. This register contains a 32-bit shift register and a 32-bit latched parallel output. It is
selected during the IDCODE instruction and when the TAP controller is in the Test-Logic-Reset state.
36 of 61

Related parts for DS3154