9005A JEWELL / MODUTEC, 9005A Datasheet

MULTIMETER DIGITAL HANDHELD, 3-1/2 DIGIT

9005A

Manufacturer Part Number
9005A
Description
MULTIMETER DIGITAL HANDHELD, 3-1/2 DIGIT
Manufacturer
JEWELL / MODUTEC
Datasheet

Specifications of 9005A

Dmm Type
Handheld
Voltage Measuring Range Dc
1000
Voltage Measuring Range Ac
750
Current Measuring Range Dc
20µA To 10A
Current Measuring Range Ac
200µA To 10A
Lead Free Status / RoHS Status
na
TRIPLETT
Model
9005-A
Digital Multimeter
Instruction Manual

9005A Summary of contents

Page 1

TRIPLETT Model 9005-A Digital Multimeter Instruction Manual ...

Page 2

CONTENTS 1. Introduction 2. Safety Rules and Warnings 3. International Symbols 4. Product Features 5. Specifications 6. Front Panel 7. Measurement Procedures 8. Using the Holster 9. Maintenance 10. Accessories 11. Warranty 1: INTRODUCTION The Triplett Model 9005 ...

Page 3

Do not use this meter with its case open, or with parts removed. Doing so may damage the meter and/or injure the user. 2.4 When using this meter in schools and workshops, responsible teachers or skilled personnel must control ...

Page 4

Insert the test leads in the jacks specified in the instructions for performing particular tests. Inserting the test leads in incorrect jacks can damage the meter and/or injure the user. 2.14 Do not exceed the maximum voltage or current ...

Page 5

Do not use this meter to make measurements in adverse environments such as rain, snow, fog, or locations with steam, explosive gases or dusts. Doing so may damage the meter and/or injure the user. 2.25 Do not use meter ...

Page 6

Do not use this meter to measure current in circuits whose open circuit voltage exceeds 250V AC/DC. The meter’s fuses are rated at 250V max. Failure to observe this precaution may result in damage to the meter or injury ...

Page 7

Avoid usage near strong magnetic fields (magnets, loudspeakers, transformers, motors, coils, relays, contactors, electromagnets, etc.). The meter may display readings that are in error, causing the user to misinterpret the hazards present. For example, the meter may indicate a ...

Page 8

INTERNATIONAL SYMBOLS The following International Symbols may be used in this manual and on the case of the meter to identify, caution, or warn the user of important product limitations or important operational procedures that must be followed to ...

Page 9

SPECIFICATIONS Display: 1.15" (29mm) high LCD Display Resolution: 2000 counts, 0000 to 1999 Overrange Indication: First digit displays “1”, remaining digits are blank Measurement Rate measurements per second Low Battery Annunciator: Operating Conditions: Temperature ...

Page 10

Note: a) The following accuracy specifications are valid at 23 degrees C, +/- 5 degrees C, Relative Humidity less than 75% b) The specifications are in the form “ +/- ( reading + LSD)” where LSD is “Least ...

Page 11

µ ...

Page 12

FRONT PANEL Liquid Crystal Display 2) POWER Button 3) Rotary Function / Range Switch 4) Holster 5) HOLD Button 6) Transistor Socket 7) Input Jacks ...

Page 13

MEASUREMENT PROCEDURES Do not use the meter when the low battery annunciator This may cause the meter to produce inaccurate readings, and lead the user to believe that no hazard exists, when, in fact, dangerous voltages 7.1 Using the ...

Page 14

Set the RANGE switch voltage is unknown, set the RANGE switch to the highest V If the input voltage is higher than the previously stated limits, do not attempt to measure! 7.3.3 Connect the test probes ...

Page 15

Connect the test probes to circuit being measured. The LCD will display the AC voltage. 7.4.4 If the display indicates overrange, i.e. “1- - -”, disconnect the test probes from the circuit and rotate the RANGE switch to the ...

Page 16

If the display indicates overrange, i.e. “1- - -”, disconnect the test probes from the circuit and reconnect the red test lead to the 10A jack. Set the RANGE switch to the 10A the circuit. Read the value from ...

Page 17

If the display indicates overrange, i.e. “1- - -”, disconnect the test probes from the circuit and reconnect the red test lead to the 10A jack. Set the RANGE switch to the 10 A circuit. Read the value from ...

Page 18

Notes: a) The 2M, 20M, and 200M ranges require several seconds to stabilize. b) The 200M range reads 10 LSD high. To obtain an accurate reading, subtract 10 LSD from the indicated value on the LCD obtain the ...

Page 19

Set the RANGE switch to the Diode Test / Continuity Beeper “ ” range. 7.9.3 Connect the test probes to the device or circuit to be tested. To test a simple diode, connect the red test probe to the ...

Page 20

USING THE HOLSTER A protective holster is provided with the Model 9005-A. This vinyl holster pro- vides a measure of protection from the everyday rigors that products of this type are often subjected to. Molded into the holster are ...

Page 21

MAINTENANCE Your Triplett Model 9005-A DMM is a precision measuring instrument and, when used as described in this manual, should not require maintenance. However, periodic calibration of the meter will insure that it is accurate and per- forming in ...

Page 22

Remove the 9 volt battery and replace with a fresh battery (PN 37-48). 9.1.5 Carefully install the fresh battery back into the meter, making sure that the battery wires will not be pinched when the case of the meter ...

Page 23

ACCESSORIES 10.1 The Triplett Model 9005-A package contains the following items: The Model 9005-A DMM Test leads w/ Screw-On Alligator Clips (Triplett PN 79-760) Holster (Triplett PN 10-4281) Instruction Manual (Triplett PN 84-852) 10.2 Replacement Fuse 2A/250V FAST, 5 ...

Page 24

... Our obligation under this warranty is limited to repairing, replacing, or making refund on any instrument or test equipment which proves to be defective within three years from the date of original purchase. This warranty does not apply to any of our products which have been repaired or altered ...

Page 25

NOTES 24 ...