TP750 Tektronix, TP750 Datasheet - Page 6

TEST PROBE, RTD TEMPERATURE

TP750

Manufacturer Part Number
TP750
Description
TEST PROBE, RTD TEMPERATURE
Manufacturer
Tektronix
Datasheet

Specifications of TP750

Test Probe Type
RTD Temperature
Test Probe Functions
Temperature
Accuracy
± 0.055°C
Temperature Measuring Range
-200°C To +300°C
Equipment Type
Temperature Probe
Color
Black, Red
Measured Components
Temperature
For Use With
DMM4050 Digital Multimeter
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na
Data Sheet
AC Voltage Specifications
AC Voltage specifications are for AC sinewave signals >5% of range. For inputs from
1% to 5% of range and <50 kHz, add an additional error of 0.1% of range, and for
50 kHz to 100 kHz, add 0.13% of range.
Input Characteristics
Accuracy
*
6
Characteristic
Maximum Input
Measurement Method
AC Filter Bandwidth
Common Mode
Rejection
Maximum Crest Factor
Additional Crest Factor
Errors (<100 Hz)
Range
200 mV
2 V
20 V
200 V
750 V
Range
200 mV
2 V
20 V
200 V
750 V
3
Uncertainty given as ±(% of reading + % of range).
www.tektronix.com
Description
750 V
AC-coupled true RMS. Measures the AC component of
input with up to 1000 VDC bias on any range
20 Hz – 100 kHz
60 dB at 50 Hz or 60 Hz (1 kΩ unbalance)
3:1 at Full Scale
Crest Factor 1-2, 0.05% of full scale
Crest Factor 2-3, 0.2% of full scale
Only applies for non-sinusoid signals
RMS
or 1000 V peak or 8 × 10
(5½ Digits)
Full Scale
199.999 mV
1.99999 V
19.9999 V
199.999 V
750.00 V
50 kHz – 100 kHz
50 kHz – 100 kHz
50 kHz – 100 kHz
50 kHz – 100 kHz
50 kHz – 100 kHz
20 kHz – 50 kHz
20 kHz – 50 kHz
20 kHz – 50 kHz
20 kHz – 50 kHz
20 kHz – 50 kHz
45 Hz – 20 kHz
45 Hz – 20 kHz
45 Hz – 20 kHz
45 Hz – 20 kHz
45 Hz – 20 kHz
20 Hz – 45 Hz
20 Hz – 45 Hz
20 Hz – 45 Hz
20 Hz – 45 Hz
20 Hz – 45 Hz
Frequency
7
Volts-Hertz product
100 μV
10 mV
10 μV
Slow
1 mV
1 μV
23 °C ±5 °C
0.15 + 0.05
0.15 + 0.05
0.15 + 0.05
0.15 + 0.05
0.15 + 0.05
0.8 + 0.05
0.3 + 0.05
0.8 + 0.05
0.8 + 0.05
0.3 + 0.05
0.8 + 0.05
0.8 + 0.05
0.3 + 0.05
0.8 + 0.05
0.8 + 0.05
0.3 + 0.05
0.8 + 0.05
0.8 + 0.05
0.3 + 0.05
0.8 + 0.05
90 days
Resolution
Uncertainty*
Medium
1000 μV
100 mV
100 μV
10 mV
10 μV
3
23 °C ±5 °C
0.35 + 0.05
0.35 + 0.05
0.35 + 0.05
0.35 + 0.05
0.35 + 0.05
0.9 + 0.05
0.2 + 0.05
0.9 + 0.05
0.9 + 0.05
0.2 + 0.05
0.9 + 0.05
0.9 + 0.05
0.2 + 0.05
0.9 + 0.05
0.9 + 0.05
0.2 + 0.05
0.9 + 0.05
0.9 + 0.05
0.2 + 0.05
0.9 + 0.05
1 year
1000 μV
100 mV
100 μV
10 mV
10 μV
Fast
Temperature Coefficient/°C
Outside 18 – 28 °C
1 MΩ ±2% shunted by
Input Impedance
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.05 + 0.01
0.05 + 0.01
0.05 + 0.01
0.05 + 0.01
0.05 + 0.01
<100 pf