1132A AGILENT TECHNOLOGIES, 1132A Datasheet - Page 26

TEST PROBE, OSCILLOSCOPE

1132A

Manufacturer Part Number
1132A
Description
TEST PROBE, OSCILLOSCOPE
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of 1132A

Test Probe Type
Oscilloscope
Test Probe Functions
High Frequency
Accuracy
± 3%
For Use With
Infiniium Series Oscilliscopes
Lead Free Status / RoHS Status
na
Active Differential Voltage Probes
Agilent 1153A Low-Bandwidth Active Differential Voltage
Specifications
Operating Characteristics
Bandwidth (–3 dB)
Rise time
dc gain accuracy*
dc attenuator accuracy
Linear differential input range
dc offset
Common mode operating range
Maximum allowable input voltage*
Input coupling
CMRR*
ac coupling
dc thermal drift
Input RC
Output termination impedance
Safety
Environmental Characteristics
Temperature
Humidity
Altitude
* Denotes specified parameters. All others are characteristics.
[1] For maximum signal fidelity, above 100 MHz, limit probe output into 50 Ω to ≤ 300 mV peak-to-peak.
26
dc to 200 MHz [1]
1.75 ns calculated from t
2% (with 50 ± 0.1 Ω load)
2%
±0.3 V (1:1); ±3.0 V (10:1); ±30 V (100:1)
±18 V (1:1); ±180 V (10:1); ±500 V (100:1)
dc: ±18 V (1:1); ±180 V (10:1); ±500 V (100:1)
dc to 30 Hz: linearly decreased to 30 Hz value
30 Hz to 200 MHz: ±0.5 V (1:1); ±5 V (10:1); ±50 V (100:1)
(voltages are peak voltage)
200 V (dc + peak ac) CAT I, 1:1;
500 V (dc + peak ac) CAT I, with attenuators common
or differential modes
dc, LF reject, and ac.
ac coupling is provided via an adapter that attaches to
the probe. LF reject response (–3 dB) is selectable
independent of attenuators at 1.7 Hz (LFR1) and
0.14 Hz (LFR2).
See graph on next page.
15 Hz (1:1); 1.5 Hz (10:1).
Low-Frequency Response (–3 dB) with ac coupling
adapter and input 1.5 Hz (100:1) coupling set to dc.
≤ 50 µV dc/°C
1:1
10:1
100:1 R: 10 MΩ C: 2.0 pF
50 Ω
Meets IEC 1010-2-31
Operating: 0° C to +55° C;
Non-operating: –40° C to +70° C
Operating: 95% relative humidity at 40° C;
Non-operating: 90% relative humidity at +65° C
Operating: Up to 4,600 m (15,000 ft);
Non-operating: Up to 15,300 m (50,000 ft)
R: 1 MΩ
R: 9 MΩ
C: 7 pF
C: 3.5 pF
r
= (0.35/bandwidth)