P87C52X2BA NXP Semiconductors, P87C52X2BA Datasheet - Page 18

no-image

P87C52X2BA

Manufacturer Part Number
P87C52X2BA
Description
MCU 8-Bit 87C 80C51 CISC 8KB EPROM 5V 44-Pin PLCC Tube
Manufacturer
NXP Semiconductors
Datasheet

Specifications of P87C52X2BA

Package
44PLCC
Device Core
80C51
Family Name
87C
Maximum Speed
33 MHz
Operating Supply Voltage
5 V
Data Bus Width
8 Bit
Number Of Programmable I/os
32
Interface Type
UART
Number Of Timers
3
Ram Size
256 Byte
Program Memory Size
8 KB
Program Memory Type
EPROM
Operating Temperature
0 to 70 °C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P87C52X2BA
Manufacturer:
NXPL
Quantity:
5 510
Part Number:
P87C52X2BA
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
P87C52X2BA,512
Manufacturer:
Cypress
Quantity:
730
Part Number:
P87C52X2BA,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
Table 4. Timer 2 Operating Modes
2003 Jan 24
80C51 8-bit microcontroller family
4K/8K/16K/32K ROM/OTP, low voltage (2.7 to 5.5 V),
low power, high speed (30/33 MHz)
T2CON
RCLK + TCLK
Symbol
TF2
EXF2
RCLK
TCLK
EXEN2
TR2
C/T2
CP/RL2
X
0
0
1
Bit Addressable
Address = C8H
Position
T2CON.7
T2CON.6
T2CON.5
T2CON.4
T2CON.3
T2CON.2
T2CON.1
T2CON.0
TF2
7
Name and Significance
Timer 2 overflow flag set by a Timer 2 overflow and must be cleared by software. TF2 will not be set
when either RCLK or TCLK = 1.
Timer 2 external flag set when either a capture or reload is caused by a negative transition on T2EX and
EXEN2 = 1. When Timer 2 interrupt is enabled, EXF2 = 1 will cause the CPU to vector to the Timer 2
interrupt routine. EXF2 must be cleared by software. EXF2 does not cause an interrupt in up/down
counter mode (DCEN = 1).
Receive clock flag. When set, causes the serial port to use Timer 2 overflow pulses for its receive clock
in modes 1 and 3. RCLK = 0 causes Timer 1 overflow to be used for the receive clock.
Transmit clock flag. When set, causes the serial port to use Timer 2 overflow pulses for its transmit clock
in modes 1 and 3. TCLK = 0 causes Timer 1 overflows to be used for the transmit clock.
Timer 2 external enable flag. When set, allows a capture or reload to occur as a result of a negative
transition on T2EX if Timer 2 is not being used to clock the serial port. EXEN2 = 0 causes Timer 2 to
ignore events at T2EX.
Start/stop control for Timer 2. A logic 1 starts the timer.
Timer or counter select. (Timer 2)
Capture/Reload flag. When set, captures will occur on negative transitions at T2EX if EXEN2 = 1. When
cleared, auto-reloads will occur either with Timer 2 overflows or negative transitions at T2EX when
EXEN2 = 1. When either RCLK = 1 or TCLK = 1, this bit is ignored and the timer is forced to auto-reload
on Timer 2 overflow.
CP/RL2
X
X
0
1
EXF2
6
0 = Internal timer (OSC/12 in 12-clock mode or OSC/6 in 6-clock mode)
1 = External event counter (falling edge triggered).
Figure 6. Timer/Counter 2 (T2CON) Control Register
RCLK
5
TCLK
TR2
4
1
1
1
0
18
EXEN2
3
16-bit Auto-reload
16-bit Capture
Baud rate generator
(off)
TR2
2
C/T2
1
P80C3xX2; P80C5xX2;
Reset Value = 00H
MODE
CP/RL2
0
P87C5xX2
SU01621
Product data

Related parts for P87C52X2BA