MAX2041ETP+ Maxim Integrated Products, MAX2041ETP+ Datasheet - Page 12

no-image

MAX2041ETP+

Manufacturer Part Number
MAX2041ETP+
Description
Up-Down Converters IC MIXER UP/DWN HI LIN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX2041ETP+

Maximum Input Frequency
3000 MHz
Maximum Power Dissipation
2200 mW
Maximum Operating Frequency
350 MHz
Maximum Power Gain
- 7.1 dB
Operating Supply Voltage
5 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Package / Case
TQFN-20 EP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
High-Linearity, 1700MHz to 3000MHz Upconversion/
Downconversion Mixer with LO Buffer/Switch
The MAX2041 can operate either as a downconverter
or an upconverter mixer that provides 7.2dB of conver-
sion loss with a typical 7.4dB noise figure. IIP3 is
+33.5dBm for both upconversion and downconversion
operation. The integrated baluns and matching circuitry
allow for 50Ω single-ended interfaces to the RF port
and two LO ports. The RF port can be used as an input
for downconversion or an output for upconversion. A
single-pole, double-throw (SPDT) switch provides 50ns
switching time between the two LO inputs with 43dB of
LO-to-LO isolation. Furthermore, the integrated LO
buffer provides a high drive level to the mixer core,
reducing the LO drive required at the MAX2041’s
inputs to a range of -3dBm to +3dBm. The IF port incor-
porates a differential output for downconversion, which
is ideal for providing enhanced IIP2 performance. For
upconversion, the IF port is a differential input.
Specifications are guaranteed over broad frequency
ranges to allow for use in UMTS, cdma2000, 2G/2.5G/3G
DCS 1800, PCS 1900, and WiMAX base stations. The
MAX2041 is specified to operate over an RF frequency
range of 1700MHz to 3000MHz, an LO frequency range
of 1900MHz to 3000MHz, and an IF frequency range of
DC to 350MHz. Operation beyond these ranges is pos-
sible; see the Typical Operating Characteristics for
additional details.
12
4, 5, 10, 12,
13, 16, 17,
1, 6, 8, 14
18, 19
______________________________________________________________________________________
PIN
EP
20
11
15
2
3
7
9
LOBIAS
LOSEL
IF-, IF+
NAME
GND
GND
V
TAP
LO1
LO2
RF
CC
Detailed Description
Power-Supply Connection. Bypass each V
Application Circuit.
Single-Ended 50Ω RF Input/Output. This port is internally matched and DC shorted to GND through a
balun.
Center Tap of the Internal RF Balun. Bypass to GND with capacitors close to the IC, as shown in the
Typical Application Circuit.
Ground
Bias Resistor for Internal LO Buffer. Connect a 549Ω ±1% resistor from LOBIAS to the power supply.
Local Oscillator Select. Logic control input for selecting LO1 or LO2.
Local Oscillator Input 1. Drive LOSEL low to select LO1.
Local Oscillator Input 2. Drive LOSEL high to select LO2.
Differential IF Input/Outputs
Exposed Ground Paddle. Solder the exposed paddle to the ground plane using multiple vias.
This device can operate equally well in low-side LO injec-
tion applications as long as the LO frequency range is
between 1900MHz and 3000MHz. If an LO frequency
range below 1900MHz is desired, refer to the MAX2039.
For using the MAX2041 as a downconverter, the RF input
is internally matched to 50Ω, requiring no external match-
ing components. A DC-blocking capacitor is required
since the input is internally DC shorted to ground through
the on-chip balun. The RF return loss is typically better
than 17dB over a 1400MHz to 3000MHz frequency range.
For upconverter operation, the RF port is a single-ended
output similarly matched to 50Ω.
The MAX2041 can be used for either high-side or low-
side injection applications with a 1900MHz to 3000MHz
LO frequency range. For a device with a 1500MHz to
2000MHz LO frequency range, refer to the MAX2039
data sheet. As an added feature, the MAX2041 includes
an internal LO SPDT switch that can be used for frequen-
cy-hopping applications. The switch selects one of the
two single-ended LO ports, allowing the external oscillator
to settle on a particular frequency before it is switched in.
LO switching time is typically less than 50ns, which is
more than adequate for virtually all GSM applications. If
frequency hopping is not employed, set the switch to
either of the LO inputs. The switch is controlled by a
digital input (LOSEL): logic-high selects LO2, logic-low
selects LO1. To avoid damage to the part, voltage MUST
CC
pin to GND with capacitors as shown in the Typical
FUNCTION
LO Inputs, Buffer, and Balun
Pin Description
RF Port and Balun

Related parts for MAX2041ETP+