TJA1054AT NXP Semiconductors, TJA1054AT Datasheet - Page 4

TRANSCEIVER, CAN FAULT TOL, SO-14

TJA1054AT

Manufacturer Part Number
TJA1054AT
Description
TRANSCEIVER, CAN FAULT TOL, SO-14
Manufacturer
NXP Semiconductors
Datasheet

Specifications of TJA1054AT

Number Of Transceivers
1
Power Down Mode
Sleep/Standby
Operating Supply Voltage (max)
5.25V
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (min)
4.75V
Package Type
SO
Supply Current
0.125/27mA
Operating Temperature (max)
150C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
14
Supply Voltage Range
4.75V To 5.25V
Operating Temperature Range
-40°C To +150°C
Digital Ic Case Style
SOIC
No. Of Pins
14
Svhc
No SVHC (18-Jun-2010)
Package / Case
SO
Base Number
1054
Supply
RoHS Compliant
Ic Function
CAN Transceiver
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TJA1054AT
Manufacturer:
NXP
Quantity:
10 000
Part Number:
TJA1054AT
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
TJA1054AT,518
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
TJA1054AT/S400
Manufacturer:
PHI
Quantity:
149
Part Number:
TJA1054AT/VM
Manufacturer:
NXP
Quantity:
72 145
Part Number:
TJA1054AT/VM
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
TJA1054AT/VM,518
Manufacturer:
Maxim
Quantity:
39
Part Number:
TJA1054ATD-T
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
NXP Semiconductors
6. Pinning information
TJA1054A
Product data sheet
6.1 Pinning
6.2 Pin description
Table 3.
Symbol
INH
TXD
RXD
ERR
STB
EN
WAKE
RTH
RTL
V
CANH
CANL
GND
BAT
Fig 2. Pin configuration
CC
Pin description
All information provided in this document is subject to legal disclaimers.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Rev. 5 — 3 August 2010
Description
inhibit output for switching an external voltage regulator if a
wake-up signal occurs
transmit data input for activating the driver to the bus lines
receive data output for reading out the data from the bus lines
error, wake-up and power-on indication output; active LOW in
normal operating mode when a bus failure is detected; active LOW
in standby and sleep mode when a wake-up is detected; active
LOW in power-on standby when a V
detected
standby digital control signal input; together with the input signal
on pin EN this input determines the state of the transceiver;
see
enable digital control signal input; together with the input signal on
pin STB this input determines the state of the transceiver;
see
local wake-up signal input (active LOW); both falling and rising
edges are detected
termination resistor connection; in case of a CANH bus wire error
the line is terminated with a predefined impedance
termination resistor connection; in case of a CANL bus wire error
the line is terminated with a predefined impedance
supply voltage
HIGH-level CAN bus line
LOW-level CAN bus line
ground
battery supply voltage
WAKE
RXD
ERR
TXD
STB
INH
EN
Table 5
Table 5
1
2
3
4
5
6
7
and
and
TJA1054AT
Figure 3
Figure 3
001aaf609
14
13
12
11
10
9
8
BAT
GND
CANL
CANH
V
RTL
RTH
CC
Fault-tolerant CAN transceiver
BAT
power-on event is
TJA1054A
© NXP B.V. 2010. All rights reserved.
4 of 27