UJA1065TW/3V3.512 NXP Semiconductors, UJA1065TW/3V3.512 Datasheet - Page 24

no-image

UJA1065TW/3V3.512

Manufacturer Part Number
UJA1065TW/3V3.512
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of UJA1065TW/3V3.512

Number Of Transceivers
1
Power Down Mode
Standby
Operating Supply Voltage (min)
5.5V
Supply Current
10mA
Operating Temperature (max)
125C
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Lead Free Status / RoHS Status
Supplier Unconfirmed
NXP Semiconductors
UJA1065_7
Product data sheet
Fig 12. States of the RTLIN pin
6.8.1.2 Off-line mode
6.8.2 LIN wake-up
6.8.3 Termination control
supplied directly
RTLIN = ON
out of BAT42
mode change to Active mode
The LTC bit can be used to set the LIN transceiver to a Listen-only mode. The transmitter
output stage is disabled in this mode.
When leaving Active mode the LIN transmitter is disabled and the LIN receiver is
monitoring the LIN-bus for a valid wake-up.
Off-line mode is the low-power mode of the LIN transceiver. The LIN transceiver is
disabled to save supply current. Pin RXDL reflects any wake-up event at the LIN-bus.
For a remote wake-up via LIN a LIN-bus signal is required as shown in
The RTLIN pin is in one of 3 different states: RTLIN = on, RTLIN = off or RTLIN = 75 μA;
see
Fig 11. LIN wake-up timing diagram
Figure
power-on
12.
Active mode and receiver recessive > t
Active mode and receiver dominant > t
Rev. 07 — 25 February 2010
wake-up
OR mode change to Active mode
LIN
OR Off-line mode
RTLIN = OFF
AND receiver recessive > t
High-speed CAN/LIN fail-safe system basis chip
t BUS(LIN)
Off-line mode
LIN(dom)(det)
LIN(dom)(rec)
AND receiver dominant > t
LIN(dom)(rec)
Off-line mode
001aad183
001aad447
RTLIN = 75 μA
supplied directly
LIN(dom)(det)
out of BAT42
UJA1065
© NXP B.V. 2010. All rights reserved.
Figure
11.
24 of 76