SAB82525HV22XP Infineon Technologies, SAB82525HV22XP Datasheet - Page 66

no-image

SAB82525HV22XP

Manufacturer Part Number
SAB82525HV22XP
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of SAB82525HV22XP

Operating Supply Voltage (typ)
5V
Operating Supply Voltage (min)
4.75V
Operating Supply Voltage (max)
5.25V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
44
Lead Free Status / RoHS Status
Compliant
All frames exceeding this length are treated as if they have been aborted from the opposite
station, i.e. the CPU is informed via a
To distinguish between frames really aborted from the opposite station, the receive byte count
(readable from RBCH, RBCL registers) exceeds the maximum receive length (via RL6. . .RL0)
by one or two bytes in this case.
The check includes all data that is copied into the RFIFO. It does not include the address byte
(s) if address recognition is selected. It includes the RSTA value in all operating modes.
6.3 Continuous Transmission (DMA Mode only)
If data transfer from system memory to the HSCX is done by DMA (DMA bit in XBCH set), the
number of bytes to be transmitted is usually defined via the Transmit Byte Count registers
(XBCH, XBCL : bits XBC11. . .XBC0).
Setting the "Transmit Continuously" (XC) bit in XBCH, however, the byte count value is ignored
and the DMA interface of the HSCX will continuously request for transmit data any time
32 bytes can be stored in the XFIFO.
Note: If the XC bit is reset during continuous transmission, the transmit byte count becomes
6.4 Receive Length Check Feature
The HSCX offers the possibility to supervise the maximum length of received frames and to
terminate data reception in case this length is exceeded.
This feature is controlled via the special Receive Length Check Register (RLCR).
The function is enabled by setting the RC (Receive Check) bit in RLCR and programming the
maximum frame length via bits RL6. . .RL0
According to the value written to RL6. . .RL0, the maximum receive length can be adjusted in
multiples of 32-byte blocks as follows:
1)
Semiconductor Group
This feature can be used e.g. to
The frame length includes all bytes which are stored in the RFIFO.
– RME interrupt, and the
– RAB bit in RSTA register is set!
continuously transmit voice or data onto a PCM highway (clock mode 5/extended
transparent mode), or to
transmit frames exceeding the byte count programmable via XBCH, XBCL (frames with
more than 4095 bytes).
valid again, and the HSCX will request the amount of DMA transfers programmed via
XBC11. . .XBC0. Otherwise the continuous transmission is stopped when a data
underrun condition occurs in the XFIFO, i.e. the DMA controller does not transfer further
data to the HSCX. In this case continuous ’1’-s (IDLE), without appending a CRC, are
transmitted.
MAX. LENGTH = (RL + 1) 32.
1)
.
66
SAB 82525
SAB 82525
SAB 82526
SAB 82526
SAF 82525
SAF 82525
SAF 82526
SAF 82526

Related parts for SAB82525HV22XP