BK2125HS102-T Taiyo Yuden, BK2125HS102-T Datasheet - Page 33

FERRITE BEAD 1000 OHM 0805

BK2125HS102-T

Manufacturer Part Number
BK2125HS102-T
Description
FERRITE BEAD 1000 OHM 0805
Manufacturer
Taiyo Yuden
Series
BKr

Specifications of BK2125HS102-T

Impedance @ Frequency
1K Ohm @ 100MHz
Current Rating
300mA
Dc Resistance (dcr)
400.0 mOhm Max
Filter Type
Differential Mode - Single
Number Of Lines
1
Package / Case
0805 (2012 Metric)
Mounting Type
Surface Mount
Impedance
1kohm
Ferrite Grade
HS
Dc Resistance Max
0.4ohm
Dc Current Rating
300mA
Ferrite Mounting
SMD
Ferrite Case Style
0805 / 2012
Rohs Compliant
Yes
Impedance Tolerance
± 25%
Features
HS
Frequency
100MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
587-1904-2
BK2125HS102-T

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BK2125HS102-T
Manufacturer:
Taiyo Yuden
Quantity:
42 878
Part Number:
BK2125HS102-T
Manufacturer:
TAIYO/太诱
Quantity:
20 000
Part Number:
BK2125HS102-TG
Manufacturer:
TAIYO
Quantity:
8 000
Part Number:
BK2125HS102-TV
Manufacturer:
TAIYO/太诱
Quantity:
20 000
Multilayer chip inductors and beads
Note on standard condition: "standard condition" referred to herein is defined as follows:
5 to 35℃ of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20 ± 2℃ of temperature, 60 to 70% relative hu-
midity, and 86 to 106kPa of air pressure. Unless otherwise specified, all the tests are conducted under the "standard condition."
14. Damp Heat
15.Loading under
16.Loading at
RELIABILITY DATA
fSteady stateg
Damp Heat
Temperature
High
Item
BK0603
No mechanical damage, Inductance change
within±30%
Appearance: No significant abnormality
Impedance change: Within ±30%
Appearance: No significant abnormality
Impedance change: Within ±30%
BK1005
BK1608
BK2125
BK2010
ARRAY
BK3216
BKP1005
BKP1608
BKP2125
Specified Value
No
mechanica
damage.
Inductance
change:
Within
±20%
Q change:
Within
±30%
No
mechanica
damage.
Inductance
change:
Within
±20%
Q change:
Within
±30%
No
mechanica
damage.
Inductance
change:
Within
±20%
Q change:
Within
±30%
CK1608
CK2125
No
mechanica
damage.
Inductance
change:
Within
±30%
No
mechanica
damage.
Inductance
change:
Within
±30%
No
mechanica
damage.
Inductance
change:
Within
±30%
CKP2520
No
mechanica
damage.
Inductance
change:
Within
±10%
Q change:
Within
±30%
No
mechanica
damage.
Inductance
change:
Within
±10%
Q change:
Within
±30%
LK1005
No mechanica
damage.
Inductance change:
Within±10%
Q change:
Within±30%
No
mechanica
damage.
Inductance
change:
0.047 to
12.0μH:
Within
±10%
15.0 to
33.0μH:
Within
±15%
Q change:
Within
±30%
No
mechanica
damage.
Inductance
change:
0.047 to
12.0μH:
Within
±10%
15.0 to
33.0μH:
Within
±15%
Q change:
Within
±30%
LK1608
No
mechanica
damage.
Inductance
change:
Within
±10%
Q change:
Within
±30%
No
mechanica
damage.
Inductance
change:
Within
±10%
Q change:
Within
±30%
No
mechanica
damage.
Inductance
change:
Within
±10%
Q change:
Within
±30%
LK2125
HK0603 HK1005
8
No mechanica damage.
Inductance change:
Within±10%
Q change: Within±20%
No mechanica damage.
Inductance change:
Within±10%
Q change: Within±20%
No mechanica damage.
Inductance change:
Within±10%
Q change: Within±20%
HK1608
HK2125 HKQ0603 AQ105
(Note 1)
measurement shall be made after 48 ± 2 hrs of
recovery under the standard condition.
BK Series:
Temperature: 40±2℃
Humidity: 90 to 95%RH
Duration: 500
Recovery: 2 to 3 hrs of recovery under the
LK, CK, CKP, HK, HKQ, AQ Series:
Temperature: 40±2℃ (LK, CK Series)
Humidity: 90 to 95%RH
Duration: 500±12 hours
Recovery: 2 to 3 hrs of recovery under the
BK Series:
Temperature: 40±2℃ (LK Series)
Humidity: 90 to 95%RH
Duration: 500
Applied current: Rated current
Recovery: 2 to
LK, CK, CKP, HK, HKQ, AQ Series:
Temperature: 40±2℃ (LK, CK Series)
Humidity: 90 to 95%RH
Duration: 500±12 hrs
Applied current: Rated current
Recovery: 2
BK Series:
Temperature: 125±3℃
Applied current: Rated current
Duration: 500
Recovery:
LK, CK, CKP, HK, HKQ, AQ Series, BK Series P type:
Temperature: 85±2℃ (LK, CK, CKP Series)
Applied current: Rated current
Duration: 500±12 hrs
Recovery: 2 to 3 hrs of recovery under the
standard condition after the removal
standard condition after the removal
from test chamber.
standard condition after the removal
from test chamber.
standard condition after the removal
from test chamber.
standard condition after the removal
from test chamber.
standard condition after the removal
from test chamber.
from test chamber. (See Note1)
2 to 3 hrs of recovery under the
Test Methods and Remarks
to
: 85±3℃ (BK Series P type)
: 85±2℃ (HK 1608, 2125)
: 85±2℃ (HK 1005 AQ105 operating
: 125±2℃ (HK 0603, HK1005,
ー0
60±2℃ (HK , HKQ, AQ Series)
+24
ー0
ー0
temperature range ー55 to +85℃)
ー55 to +125℃)
+24
+24
operating temperature range
60±2℃ (HK , HKQ, AQ Series)
HKQ0603, AQ105)
3 hrs of recovery under the
3 hrs of recovery under the
hrs
hrs
hrs
(See Note1)
(See Note1)
(See Note1)
(See Note1)
(See Note1)
4/4
247
5

Related parts for BK2125HS102-T