FL05RD200AT Taiyo Yuden, FL05RD200AT Datasheet - Page 12
FL05RD200AT
Manufacturer Part Number
FL05RD200AT
Description
WOUND TORROIDS BEAD 20UH 1.5A
Manufacturer
Taiyo Yuden
Datasheet
1.FL05RD100AZ.pdf
(14 pages)
Specifications of FL05RD200AT
Impedance @ Frequency
2K Ohm @ 100MHz
Current Rating
1.5A
Dc Resistance (dcr)
80.00 mOhm Max
Filter Type
Differential Mode - Single
Number Of Lines
1
Package / Case
Radial
Mounting Type
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
FL05RD200AT
Manufacturer:
TE
Quantity:
1 000
△
24.Damp heat
25.Loading under damp heat
26.Loading at high temperature
!
RELIABILITY DATA
当社カタログをご使用の際には 「当社製品に関するお断り」 を必ずお読みください。
Item
△L/L:
Within±10%
Q:30min.
△L/L:
Within±10%
Q:30min.
△L/L:
Within±10%
Q:30min.
FA02
Type
△L/L:
Within±10%
△L/L:
Within±10%
△L/L:
Within±10%
CAL45
Type
(LHLP:
Appearance:
No
abnormality
Imductance
change:
Within±10%
Q change:
Within±30%
only △L/L)
LHL□□□
Specified Value
Appearance:
No
abnormality
Impedance
change:
Within±20%
FBA/FBR
Refer to
individual
specification
FL05□
Type
Appearance:
No
abnormality
Impedance
change:
Within±20%
FL06BT
Type
△
!
Please read the "Notice for TAIYO YUDEN products" before using this catalog.
FA・CA:
Temperature:40±2℃
Humidity:90∼95%RH
Duration:1000 hrs
Recovery : At least 1hr of recovery under the standard
FB:
Temperature:60±2℃
Humidity:90∼95%RH
Duration:1000 hrs
Recovery:1 to 2hrs of recovery under the standard condition
FA・CA:
Temperature:40±2℃
Humidity:90∼95%RH
Duration:1000 hrs
Applied current:Rated current
Recovery : At least 1hr of recovery under the standard
LHL□□□:
Temperature:40±2℃
Humidity:90∼95%RH
Duration:1000±24 hrs
Applied current:Rated current
Recovery:1 to 2hrs of recovery under the standard condition
FL:
Temperature:60±3℃
Humidity:90∼95%RH
Duration:500 (+12, ー0) hrs
Applied current:Rated current
Recovery:1 to 2hrs of recovery under the standard condition
FA・CA:
Temperature:85±2℃
Duration:1000 hrs
Applied current:Rated current
Recovery : At least 1hr of recovery under the standard
removal from test chamber, followed by the
measurement within 2hrs.
after the removal from the test cfamber.
removal from test chamber, followed by the
measurement within 2hrs.
after the removal from the test cfamber.
after the removal from the test cfamber.
removal from test chamber, followed by the