Datasheets
a process that requires between 700µs to 1400µs depending on
whether the data is set up for a block write. Undesirable results
may be observed if the device’s V
during this process.
In the event that the module experiences a fault and power is
lost, the user can extract the last SNAPSHOT parameters stored
during the fault by writing a 1 to SNAPSHOT_CONTROL (transfers
data from Flash memory to RAM) and then issuing a SNAPSHOT
command (reads data from RAM via SMBus).
VALUE
DATA
1
2
Copies current SNAPSHOT values from Flash memory to
RAM for immediate access using SNAPSHOT command.
Writes current SNAPSHOT values to Flash memory. Only
available when device is disabled.
TABLE 3. SNAPSHOT_CONTROL COMMAND
14
DESCRIPTION
DD
supply drops below 3.0V
ZL9101M
Non-Volatile Memory and Device Security
Features
The ZL9101M has internal non-volatile memory where user
configurations are stored. Integrated security measures ensure
that the user can only restore the module to a level that has been
made available to them.
During the initialization process, the ZL9101M checks for stored
values contained in its internal non-volatile memory. The
ZL9101M offers two internal memory storage units that are
accessible by the user as follows:
Please refer to Application Note
specific security measures via the I
1. Default Store: The ZL9101M has a default configuration that
2. User Store: The user can modify certain power supply settings
is stored in the Default Store in the controller. The module can
be restored to its default settings by issuing a
RESTORE_DEFAULT_ALL command over the SMBus.
as described in this data sheet. The user would use the User
Store to store their configuration.
AN2033
2
C/SMBus interface.
for details on how to set