G6H-2F-DC5 Omron, G6H-2F-DC5 Datasheet - Page 8

SURFACE MOUNT RELAY

G6H-2F-DC5

Manufacturer Part Number
G6H-2F-DC5
Description
SURFACE MOUNT RELAY
Manufacturer
Omron
Datasheets

Specifications of G6H-2F-DC5

Contact Form
2 Form C (DPDT)
Coil Voltage
5 VDC
Coil Current
28.1 mA
Coil Type
Non-Latching
Power Consumption
140 mW
Contact Carry Current
1 A
Termination Style
SMT
Maximum Switching Current
1 A
Current, Rating
0.5⁄1 AAC⁄ADC
Diameter, Mounting
0.031 in.
Dielectric Rating
1000 VAC
Dimensions
14 mm +⁄- 0.20 mm L x 9 mm +⁄- 0.20 mm W
Function
Sensitive
Material, Contact
Ag (Au clad)
Mounting Type
PCB
Number Of Pins
10
Power, Rating
62.5⁄33 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA, RoHS
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-40 °C
Termination
Surface Mount
Voltage, Control
5 VDC
Voltage, Rating
125 VAC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6H-2F-DC5V
Manufacturer:
OMRON
Quantity:
12 000
Company:
Part Number:
G6H-2F-DC5V
Quantity:
5 000
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. We recommend
using a latching relay (magnetic-holding relay) in this kind of circuit. If
a single-side stable model must be used in this kind of circuit, we rec-
ommend using a fail-safe circuit design that provides protection
against contact failure or coil burnout.
Claw Securing Force During Automatic Mounting
During automatic insertion of Relays, be sure to set the securing
force of each claw to the following so that the Relay’s characteristics
will be maintained.
56
Direction A: 1.96 N max.
Direction B: 4.90 N max.
Direction C: 1.96 N max.
A
C
B
Low Signal Relay
G6H
DISCONTINUED
Relay Handling
Use the Relay as soon as possible after opening the moisture-proof
package. If the Relay is left for a long time after opening the mois-
ture-proof package, the appearance may deteriorate and seal failure
may occur after the solder mounting process. To store the Relay after
opening the moisture-proof package, place it into the original pack-
age and seal the package with adhesive tape.
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.

Related parts for G6H-2F-DC5